Load management program
106 / 156
Select meter values for viewing
Wallbox:
Selection attribute for the Socket ID. Contains all valid socket numbers
and "all".
Meter reading type:
Indicates metering readings of which types shall be shown.
Only meter readings matching those criteria will be presented (e.g. “all”,
“Start Transaction”, “Transaction aligned”,…).
Meter readings table
Wallbox:
The drop down box shows the socket number of all Wallboxes that are
visible at the home screen.
Timestamp:
Timestamp of the meter reading. Might be from different attributes de-
pending on the type of meter reading.
Type:
Type of meter reading.
Display values:
Start Transaction
Meter reading at the start of a charging session.
End Transaction
Meter reading at the end of a charging session.
Intermediate
Meter reading during a charging session.
Transaction aligned socket
Clock aligned charge point
Meter readings can be either periodic (for example every ten or fifteen
minutes) or related to a charging transaction (primarily if ISO 15118 is
used). The attribute Metering Period determines how often meter read-
ings will be collected. According to ISO 15118, meter readings have to be
collected at the beginning and the end of a charging transaction as well
as frequently during the charging process (intermediate meter readings).
Value [Watth]:
Value of the meter reading. Might be from different attributes depending
on the type of meter reading.
Buttons
Export:
Press the [Export] button to show the “Download meter readings” screen.
Typical workflow: View meter values
Press the [Management] button in the toolbar.
Press the menu button [Meter Readings] at the left side of the screen. Review the current meter
readings of the wallbox.
The data shown at the meter readings screen will not be refreshed. Up to date information can be
loaded by clicking on the [Refresh] button at the bottom of the screen.
Return to the home screen by clicking on the [HOME] button .