Load management program
59 / 156
Describes whether the Charging Session is a Mode 3 charging session or
a high-level charging session.
Display values:
Basic signalling:
Mode 3 charging according to IEC 61851-1 controlled by basic signal-
ling.
ISO 15118:
Charging session controlled by high-level communication.
Point in time when the charging session has started.
[only ISO 15118 relevant]
Planned end of charging as communicated by the electric vehicle during
charge parameter discovery.
Energy consumed during the Charging session.
Point in time when the charging transaction has started.
Electric vehicles can only charge in charging transactions. A charging
transaction is terminated by a renegotiation, a charging pause, a power
cut or several other exceptions.
Point in time when the charging transaction has ended.
Code indicating the reason for the termination of a transaction.
Display values:
Vehicle unplugged:
The EV has initiated the termination by unplugging.
ISO 15118 command:
The EV has initiated the termination by unplugging.
High-level: The EV has initiated the termination by sending a com-
mand via high-level communication.
Socket failure:
The charging transaction has been terminated by the Wallbox be-
cause of a socket failure (for example overheating).
Power control:
The charging transaction has been terminated because the EV has
drawn more than the assigned power.
Housekeeping:
The EV has unplugged during a power cut, socket unavailability or
down-time of the KeContact M10.
Charging profile exceeded:
The EV has exceeded its charging profile.
Derating
The charging transaction has been terminated because the socket
has been derated.