Attaching to NEW HOLLAND and CASE Forage Harvesters
KM00321,000026E 1911FEB102/2
KM00321,0000265 1929JAN101/1
Adjust channel width
The channel width of the rotary harvesting unit can be
adjusted, if required.
Procedure:
Loosen attaching screws (A).
Cover, feed plate and scraper assembly (B) can be turned
round the feed drum (C) to modify channel width.
IMPORTANT: After adjustment, make sure that
clearance between scraper and wall of feed
drum does not exceed 5 mm (0.2 in.). See
Scrapers on Feed Drums in Section Service.
Tighten attaching screws (A).
A—Attaching screws
B—Scraper assembly
C—Feed drum
ZX1040566 —UN—13APR07ZX1040567 —UN—12APR07
Improved Channel Width Adjustment
If the section between the housing and the feed plates
is regularly blocked, adjust the channel width in such a
way that the feed plates cover the outer edge of the front
feed rolls.
ZX1041090 —UN—19SEP07
304
040810
PN=42