X5 FastMig
Operating manual - EN
Hot start
Min/Max = -30 ... +30, step 1
Default = 0
Welding function that uses higheror lower
welding current at the start of theweld.
During the Hot start period the current
changesto the normalwelding current
level. TheHot start value affects thecurrent
level and duration. Useit to prevent the
electrode from sticking to the work piece.
VRD
OFF/12V/24V
Default = OFF
Voltage reduction device (VRD) reduces
the open-circuit voltageto maintain below
a certain voltagevalue.
Current limit min
Min/Max = 10 ... machinesize A, step 1
Default = 10 A
Minimumand maximum limits for the cur-
rent adjustment.
Current limit max
Min/Max = 10 ... machinesize A, step 1
Default = 10 A
Common settings
The parameters listed here are common system settings.
Parameter Parameter value Description
Weld data
Min/Max = 0 ... 10 s, step1
0 = OFF
Default = 5 s
This defines how long theweld data sum-
mary is shown aftereach weld.
Display off
Min/Max = 5 ... 120 min, step1
Default = 5 min
Not available with MMA or gouging.
Date
Current date Adjusting date:
Select day by pressing theknob key
Adjust day by rotating theknob (Min/Max
= 1...28/29/30/31)
Select month by pressing the knob key
Adjust month by rotating theknob
(Min/Max = 1...12)
Select year by pressing the knob key
Adjust year by rotating theknob (Min/Max
= 2000...2099)
Press the knob key to end adjustment.
Time
Current time Adjusting time:
Select hours by pressing the knob key
Adjust hoursby rotating the knob
(Min/Max = 0...23)
Select minutes by pressing the knob key
Adjust minutes by rotating the knob
(Min/Max = 0...59)
Press the knob key to end adjustment.
Time counter total
>>> This shows the total arc time and power on
time.
Time counter since
>>> This shows the total arc time and power on
time sincethe last reset.
Reset time counter
Reset This resets the timecounter.
Language
Available languages
© Kemppi
66 1920960 / 2039

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi X5 FastMig Series and is the answer not in the manual?

Kemppi X5 FastMig Series Specifications

General IconGeneral
BrandKemppi
ModelX5 FastMig Series
CategoryWelding System
LanguageEnglish

Related product manuals