X8 MIG WELDER 2.5 Operation
Press the coolant circulation button after each time you change the welding gun.
For instructions on filling the cooler, see Filling cooler.
Connecting earth return cable
Warning:
Keep the welding piece bonded or connected to earth to reduce the risk of injury to users
or damage to electrical equipment.
Figure 23: The earth return cable connector on the power source
Attach the earth return cable clamp on the welding piece.
Ensure that the surface contact to the table is clean of metal oxide and paint and that the clamp is
firmly secured.
OPERATING MANUAL | EN 110
©