EasyManua.ls Logo

Kemppi X8 - Page 110

Kemppi X8
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
X8 MIG WELDER 2.5 Operation
Press the coolant circulation button after each time you change the welding gun.
For instructions on filling the cooler, see Filling cooler.
Connecting earth return cable
Warning:
Keep the welding piece bonded or connected to earth to reduce the risk of injury to users
or damage to electrical equipment.
Figure 23: The earth return cable connector on the power source
Attach the earth return cable clamp on the welding piece.
Ensure that the surface contact to the table is clean of metal oxide and paint and that the clamp is
firmly secured.
OPERATING MANUAL | EN 110
©
KEMPPI 2017 | 1817

Related product manuals