0
Configuring Activity Detection to be disabled
1
Do either of the following operations while Activity Detection is disabled:
0
Press the Activity Detection key.
0
Select a channel where Activity Detection is disabled.
0
Press the Menu
key to enter Menu Mode, and select “Activity Detection” and then select “Off”.
The “X” icon disappears and Activity Detection will be disabled.
If Activity Detection is disabled by using the Activity Detection key or
the Menu key, the Key Beep B (2 beeps) sounds from the transceiver.
Menu Zone
+
Zone 1
Channel 1
12 : 34
A
M
Configuration using KPG-D1/ D1N
0
Assigning functions to the PF
keys on the transceiver (
Transceiver Settings > Key Assignment)
0
Configuring Activity Detection (DMR Conventional) to be enabled or disabled (Personality) ( Transceiver
Settings > Personal > Personality > DMR Conventional > General)
0
Configuring Activity Detection (DMR Conventional)
to be enabled or disabled (Channel Edit) (
Transceiver
Settings > Zone/Channel > Channel Edit > DMR Conventional > General)
Man-down Detection
Man-down Detection is the function to place the transceiver automatically in Emergency Mode when the transceiver
becomes tilted and continues this position even after the time configured in Man-down Delay Time elapses.
Using this function, the transceiver can automatically enter Emergency Mode and notify a base station of the emergency
status when a user falls due to an accident.
If Man-down Pre-alert is configured, a Man-down Pre-alert (1 beep) sounds from the transceiver before the transceiver
enters Emergency Mode. The transceiver does not enter Emergency Mode if the transceiver returns from the tilted position
before the time configured in Man-down Delay Time elapses.
The threshold value of the tilt angle (Man-down Angle) to be used to detect that the transceiver is tilted can be configured
to 45 °, 60 °, or 75 °.
Note
0
Pressing the PTT switch while the time configured in Man-down Delay Time elapses pauses the Man-down Delay
Time count down. Releasing the PTT switch resumes the counting down.
0
Pressing
the Activity Reset key resets the Man-down Delay Time timer and restarts counting down from the beginning.
Configuration using KPG-D1/ D1N
0
Configuring Man-down Detection to be enabled or disabled (
Transceiver Settings > Emergency > Emergency
Information > Activity Detection)
0
Configuring Man-down Delay Time ( Transceiver Settings > Emergency > Emergency Information > Activity
Detection)
0
Configuring Man-down Pre-alert to be enabled or disabled (
Transceiver Settings > Emergency > Emergency
Information > Activity Detection)
0
Configuring Man-down
Angle (
Transceiver Settings > Emergency > Emergency Information > Activity Detection)
2 COMMUNICATIONS IN AN EMERGENCY
2.9 Placing the Transceiver in Emergency Mode by Using the Activity Detection Function
DMR FUNC (K, F)/Ver 2.20 113