Base ID
Base ID
is the target transceiver’s ID used to send GPS data or Transparent data and the following Status Messages and
Short Messages.
0
AUX Input Status Message (Mobile Only)
0
Power-on Status Message
0
Power-off Status Message
0
A Status Message that is sent by selecting a status number or directly entering a status number after the transceiver
enters Status Mode by pressing the Status key or the [0] to [9] keys on the keypad
0
A Status Message that is sent by selecting a status number or directly entering a status number after the transceiver
enters Status Mode by a user selecting “Status” from Menu Mode
0
A Status Message that is sent by pressing any of the PF keys having “Call 1” to “Call 6” allocated
0
A Status Message that is sent when any of the AUX Input ports having “Call 1” to “Call 6” allocated becomes active (Mobile
only)
0
A Short Message that is sent by entering a text string after the transceiver enters Short Message Mode by pressing the
Short Message key or the [0] to [9] keys on the keypad
0
A Short Message that is sent by entering a text string after the transceiver enters Short Message Mode by a user selecting
“Short Message” from Menu Mode
Base ID can be configured using KPG-D1/ D1N. Either Unit ID or Group ID can be configured. ID of the base station that
manages operations is normally configured for Base ID.
Configuration using KPG-D1/ D1N
Configuring Base
ID Type and Base ID (
Transceiver Settings > Personal > Personal Features > DMR Conventional
> DMR)
Emergency Status Response
Emergency Status Response
is the function to emit an Alert Tone when the transceiver receives an Emergency Status.
The transceiver behaves as follows according to the configuration using KPG-D1/ D1N.
Table 1-13 Emergency Status Response
Configuration Description
Alert Tone
The Alert Tone configured for Alert Tone (Emergency Response) sounds from the transceiver
when receiving an Emergency Status.
Horn (Mobile only)
If receiving an Emergency Status, the Alert Tone configured for Alert Tone (Emergency
Response) sounds from the transceiver and the Horn Alert port is activated.
Voice Announcement
If the transceiver receives an Emergency Status for which voice guidance is configured, the voice
guidance
is executed. If Alert Tone is enabled, voice guidance is executed after an Alert Tone is
emitted.
To configure voice guidance for Voice Announcement, “User Programmable” needs to be
configured in Voice Announcement Type.
Configuration using KPG-D1/ D1N
0
Configuring Emergency Status Response (Alert Tone/ Horn/ Voice Announcement) ( Transceiver Settings
> DMR > DMR Information > General > Emergency Status Response)
0
Configuring Alert Tone (Emergency Response) ( Transceiver Settings > DMR > DMR Information >
Conventional > Alert Tone)
1 DMR CONVENTIONAL SYSTEM
1.10 Sending and Receiving a Status Message (Status Call)
DMR FUNC (K, F)/Ver 2.20 48
CONTENTS INDEX