EasyManuals Logo

Keyscan CA250B User Manual

Default Icon
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Keyscan Inc. Technical Guide (PC109x - 04.15)
41
Figure 28 Terminate Input Wiring RTE - PIR & Push Button
Notes
Diagram illustrates CA8500B. Connections
also apply to CA250B & CA4500B.
- CA250B up to 2 Request to Exits
- CA450B up to 4 Request to Exits
- CA8500B up to 8 Request to Exits
Lens
NO
COM
PIR (Request To Exit)
NO = Normally Open
PIR
Motion Sensor RTE (Request to Exit) ½ second
pulse
Determines the amount of time the output relays
will energize when motion is detected.
RTE
Push Button
COM
NO
NO = Normally Open
“Two devices wired in
parallel to each other”
Single end of line supervision
to Request
to Exit
to Common Return
Double end of line supervision
1K
3K
COM
NO
to Request
to Exit
to Common Return
1K
COM
NO
Note
If using supervision, it is only required on the device farthest from the ACU
terminal. Example shows supervision on RTE Push Button.
No supervision
Cut View of CA8500B
Door Inputs - A
RTE Inputs - B
8
76
54321
Common
8
76
54321
AUX Inputs - C
8
76
54321
Common
Common AUX Inputs - D
16
1514
131211109
Common
AUX Inputs - E
24
2322
2120191817
KI-00132E-10-13
Supervision level set in Client software:
System VII & Vantage Site Unit Setup
Aurora Hardware Setup
Supervision level applied to all door inputs, RTE
inputs, and auxiliary inputs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyscan CA250B and is the answer not in the manual?

Keyscan CA250B Specifications

General IconGeneral
BrandKeyscan
ModelCA250B
CategoryController
LanguageEnglish