Keyscan Inc. Technical Guide (PC109x - 04.15)
74
Network Communication via Optional NETCOM2P or
NETCOM6P (Encrypted)
The NETCOM2P and NETCOM6P (encrypted) are modular serial to TCP/IP converters that plug directly into the
CIM board for network communication. The CIM circuit board with the network connection is referred to as CIM
0. This CIM unit must have a jumper on J4.
Important
The NETCOM2P and the NETCOM6P must be programmed with the Keyscan NETCOM Program Tool utility
in order to function. Refer to the NETCOM2P/CIM or NETCOM6P/CIM Programming Guides for
programming instructions.
When configuring CIM 0 with a NETCOM2P or NETCOM6P ensure the NETCOMP version is a PC1051 or
later printed circuit board. The CIM is not compatible with older NETCOM2P/6P versions.
Multiple Building Communication on a WAN
Keyscan requires a point-to-point private network where NETCOMs are used on a LAN/WAN (TCP/IP) that
integrates building to building communication for a non-reverse network application.
For a reverse network application, review the NETCOM6P (Encrypted) Installation Guide for more information
regarding network communication and configuration.