Keyscan Inc. Technical Guide (PC109x - 07.15)
121
operating maximum of a power supply. See also Keyscan and HID reader voltage/current ratings and Indala
reader voltage/current ratings.
Table 22 Keyscan Circuit Board Current Ratings
Circuit Board Type
Models
Current Rating
Control Boards
CA250B
130 mA
CA4500B
130 mA
CA8500B
130 mA
EC1500B
130 mA
EC2500B
130 mA
Output Relay Boards
OCB-8
230 mA
Communication Boards
CIM
150 mA
CIM-LINK
150 mA
NETCOM2
270 mA
NETCOM2P or NETCOM6P
140 mA
Specialty Boards
IOCB1616
400 mA
WIEEX2 Transmitter (Tx)
50 mA
WIEEX2 Receiver (Rx)
50 mA
DPS-15 Dual Power Supply Current Calculation
The DPS-15 power supply has two independent linear 1.2 Amp DC outputs the ACU supply and the AUX RDR
supply. Use the following two tables for calculating the total current required from the ACU supply and the AUX
RDR supply. Please note the ACU supply and the AUX RDR supply each have an operational limit of 1000 mA.
ACU Supply 1.2 A
Opposite Add-on Board #, enter the name of the module in the Product Description column and the board’s
current requirement in the Current Rating column. Current ratings are in the preceding table and printed on
the circuit boards. Add all the current ratings including the control board to determine the total current.
Keyscan recommends a 200 mA reserve operating margin. The total current from the ACU supply, including
the control board, should not exceed 1000 mA.

Table of Contents

Other manuals for Keyscan CA4500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keyscan CA4500B and is the answer not in the manual?

Keyscan CA4500B Specifications

General IconGeneral
BrandKeyscan
ModelCA4500B
CategoryControl Unit
LanguageEnglish

Related product manuals