Keyscan Inc. Technical Guide (PC109x - 07.15)
81
Figure 60 HID iClass KR90L Long Range Reader
Shield not connected.
Isolate with electrical tape.
to separate
12 VDC power
supply with
minimum
2 Amps per R90
3 pairs shielded
18 AWG
500 ft (152.4 m)
maximum
Shield
ACU Ground
Lug
White
Green
Red +
Black
Brown
Black -
Black
Green
White
Red
Brown
Terminal block on iClass SE
R90 reader
HID iClass KR90L
Current Draw @ 12VDC
In-rush current - 1300 mA
Normal standby - 110 mA
Peak - 300 mA
Reader terminal on control board
LED D1
WHT
D0
GRN
PWR
RED
GND
BLK
C1
(BEEP)
KI-00501E-06-15
Hold [P1-7]
P1
P2
Red [P1-6]
Drain [P1-5]
+VDC [P1-4]
GND [P1-3]
GRN [P1-2]
Beep [P1-1]
GPIO1 [P2-7]
GPIO2 [P2-6]
OC/TMPR [P2-5]
DATA1/CLK [P2-4]
DATA0/DATA [P2-3]
GPIO3 [P2-2]
GPIO4 [P2-1]
Blue
Blue*
* Blue pre-alert optional

Table of Contents