64 Keysight M9036A PXIe Embedded Controller User Guide
Service Memory Modules
Memory Modules
Keysight’s M9036A has two memory connectors; one on top of the other. The
module comes standard with either one 4GB memory module (installed in the
bottom position) or two 2GB memory modules. Optionally, two 4GB memory
modules can be installed bringing the total memory to 8GB. No more than 8GB
memory may be used with the module. The controller uses DDR3 1333 SODIMM
memory modules.
To remove memory modules from the controller:
1 Power off the PXIe chassis.
2 Remove the M9036A controller from the PXIe chassis.
3 Position the controller, top side up on the workbench as shown in Figure 18.
Always observe ESD precautions. See “Electrostatic Discharge” on
page 53.