PLZ-4W Specifications 9-5
Switching mode
*1 The minimum time width is 10 s. Between 5 kHz and 20 kHz, the maximum duty cycle is limited by the mini-
mum time width.
Slew rate
*1 In CC mode. The maximum slew rate of each range is 1/10th the value in CR mode.
*2 Time to reach from 10 % to 90 % when the current is varied from 2 % to 100 % (20 % to 100 % in M range) of the
rated current.
Slew rate resolution
Soft start
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operation mode
CC and CR
Duty cycle setting
5 % – 95 %
*1
, 0.1 % step
Selectable frequency range 1 Hz – 20 kHz
Frequency
resolution
1 Hz – 10 Hz
0.1 Hz
10 Hz – 100 Hz
1 Hz
100 Hz – 1 kHz
10 Hz
1 kHz – 20 kHz
100 Hz
Frequency accuracy of setting (0.5 % of set)
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Setting range
*1
Range
H
2.5 mA/s
– 2.5 A/s
5 mA/s
– 5 A/s
16 mA/s
– 16 A/s
2.5 mA/s
– 2.5 A/s
10 mA/s
– 10 A/s
M
250 A/s
– 250 mA/s
500 A/s
– 500 mA/s
1.6 mA/s
– 1.6 A/s
250 A/s
– 250 mA/s
1 mA/s
– 1 A/s
L
25 A/s
– 25 mA/s
50 A/s
– 50 mA/s
160 A/s
– 160 mA/s
25 A/s
– 25 mA/s
10
0 A/s
– 100 mA/s
Resolution See below.
Accuracy of setting
*2
(10 % of set + 5 s)
PLZ164W
PLZ164WA
Setting
25 A/s
– 250 A/s
250 A/s
– 2.5 mA/s
2.5 mA/s
– 25 mA/s
25 mA/s
– 250 mA/s
250 mA/s
– 2.5 A/s
Resolution 100 nA 1 A10 A100 A1 mA
PLZ334W
Setting
50 A/s
– 500 A/s
500 A/s
– 5 mA/s
5 mA/s
– 50 mA/s
50 mA/s
– 500 mA/s
500 mA/s
– 5 A/s
Resolution 200 nA 2 A20 A200 A2 mA
PLZ664WA
Setting
100 A/s
– 1 mA/s
1 mA/s
– 10 mA/s
10 mA/s
– 100 mA/s
100 mA/s
– 1 A/s
1 A/s
– 10 A/s
Resolution 400 nA 4 A40 A 400 A4 mA
PLZ1004W
Setting
160 mA/ms
– 1.6 mA/ms
1.6 mA/ms
– 16 mA/ms
16 mA/ms
– 160 mA/ms
160 mA/s
– 1.6 A/s
1.6 A/s
– 16 A/s
Resolution 600 nA 6 mA 60 mA 600 mA
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operation mode CC and CR
Selectable time range 1, 2, 5, 10, 20, 50, 100, or 200 ms
Time accuracy (30 % of set +100 s)