EasyManua.ls Logo

Kimaldi BioMax2 - Communication Via KSP UDP

Kimaldi BioMax2
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BioMax2 / KBio2-Online
Installation and Programming Manual
www.kimaldi.com Page 29 of 91
7.3.4. Communication via KSP UDP
When using protocol KSP-UDP (port 6000 on BioMax2/KBio2), everything explained in
the previous section still applies:
• Parameters CFG_Serial_Port_Host or CFG_Serial_Port_Reader must be properly
configured ($98 or $99 according to the baud rate for Bio-OCX, $20, $21 o $22
according to the baud rate for KRD13Mv2).
Send to UART and Reception from UART may be used for communication.
However, a more convenient method exists:
• Our BioMax2/KBio2 board has a KSP address (see
Subsection 6.3.2.), made of an
Application_ID between 11 and 14, plus Node_ID between 1 and 254. For
instance, 14.4 (
$0E.$04 in Hexadecimal)
• In such case, the peripheral board connected to UART0 will have a KSP address
incremented in 64 units (
$40) as its Application_ID. For instance, 78.4
(
$4E.$04).
• And the peripheral board connected to UART1 will have a KSP address
incremented in 128 units ($80) as its Application_ID. For instance, 142.4
($8E.$04).
That way, we may operate with up to 3 different electronic boards, through KSP (but
only the main one will appear on Kimaldi Localisation Service)