7.3.4. Communication via KSP UDP
When using protocol KSP-UDP (port 6000 on BioMax2/KBio2), everything explained in
the previous section still applies:
• Parameters CFG_Serial_Port_Host or CFG_Serial_Port_Reader must be properly
configured ($98 or $99 according to the baud rate for Bio-OCX, $20, $21 o $22
according to the baud rate for KRD13Mv2).
• Send to UART and Reception from UART may be used for communication.
However, a more convenient method exists:
• Our BioMax2/KBio2 board has a KSP address (see
Subsection 6.3.2.), made of an
Application_ID between 11 and 14, plus Node_ID between 1 and 254. For
instance, 14.4 (
$0E.$04 in Hexadecimal)
• In such case, the peripheral board connected to UART0 will have a KSP address
incremented in 64 units (
$40) as its Application_ID. For instance, 78.4
(
$4E.$04).
• And the peripheral board connected to UART1 will have a KSP address
incremented in 128 units ($80) as its Application_ID. For instance, 142.4
($8E.$04).
That way, we may operate with up to 3 different electronic boards, through KSP (but
only the main one will appear on Kimaldi Localisation Service)