Installation and Programming Manual
www.kimaldi.com Page 41 of 91
8.1.5. Digital output timing
For all the parameters described in the table, the configuration value corresponds to
the time in tenths of second that they are to remain enabled:
- Whenever a port enabled in CFG_Reader_BuzOK receives a correct reading, the
external green LED (CFG_TempGREEN_OK) and the buzzer will activate
(CFG_TempBuzz_OK) .
- Whenever a port enabled in CFG_Reader_ BuzError receives an incorrect
reading, the external red LED (CFG_TempRED_Fail) and the buzzer will
activate (CFG_TempBuzz_Fail).
- When the display is written on ( Write Display ), the backlighting will be automat-
ically enabled.
Permitted values:
- 0xFF: Permanently enabled.
- 0x01 .. 0xFE: Timing in tenths of a second.
- 0x00: Timing disabled.
Default value: depending on parameter (see table)
Internal buzzer timings may also be configured (FW 0x61.33 and later):
Table 8: Digital output timing
Num Description
Def.
$1F
CFG_TempGREEN_OK
Green LED timing upon correct reading $0A
$20
CFG_TempRED_Fail
Red LED timing upon incorrect reading $14
$21
CFG_TempBuzz_OK
Buzzer timing upon correct reading $02
$22
CFG_TempBuzz_Fail
Buzzer timing upon incorrect reading $06
$23
CFG_TempBacklit
Display backlighting $32
Table 9: Internal buzzer timing
Num Description
Def.
$06
CFG_TempBuzz1_OK
Internal buzzer, correct key pressing $06
$07
CFG_TempBuzz1_Fail
Internal buzzer, upon error $78