EasyManua.ls Logo

Kimaldi BioMax2 - Switch Led;Beeper; Close Relay

Kimaldi BioMax2
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BioMax2 / KBio2-Online
Installation and Programming Manual
www.kimaldi.com Page 57 of 91
9.6.8. Switch Led/Beeper
Function: This switches one of the LEDs or the beeper on or off.
9.6.9. Close Relay
Instruction
OP 0x31
NA 0x0002
ARG Byte 1: 0x00: Green LED
0x01: Red LED
0x02: external beeper
0x03: internal beeper
Byte 2: 0x00: off.
<>0x00: on
Response
OP 0x31
NA 0x0000
ARG None
Instruction
OP 0x40
NA 0x0002
ARG Byte 1: relay number to be enabled (from 0 to 3 in DB module)
Byte 2: enabling time 0x00 to 0xFE tenths of second
Response
OP 0x40
NA 0x0000
ARG None

Table of Contents