Function: Closes designated relay for the specified time.
If bit 5 of CFG_ECHO is enabled (see
Subsection 8.1.2.), the BioMax2 / KBio2-Online
electronics can notify the end of a timing. In this case, an event is generated indicating
the number of the relay to have returned to standby status.
9.6.10. Switch Relay
Function: Closes or opens designated relay.
Event
OP 0x40
NA 0x0002
ARG Byte 1: relay number to end the timing (from 0 to 3 in DB module)
Byte 2: always 0x00
Instruction
OP 0x41
NA 0x0002
ARG Byte 1: relay number to be enabled (from 0 to 3 in DB module)
Byte 2: 0x00: open.
<>0x00: enabled (closed)
Response
OP 0x41
NA 0x0000
ARG None