BioMax2 / KBio2-Online
Installation and Programming Manual
www.kimaldi.com Page 56 of 91
9.6.7. Activate Led/Beeper Time
Function: Activates one of the LEDs or the beeper for the specified time.
If bit 5 of CFG_ECHO is enabled (see Subsection 8.1.2.), the BioMax2 / KBio2-Online
electronics can indicate the end of a timing. In this case, an event is generated indicating
the number of the relay to have returned to standby status.
Instruction
OP 0x30
NA 0x0002
ARG Byte 1: 0x00: Green LED
0x01: Red LED
0x02: external beeper
0x03: internal beeper
Byte 2: enabling time 0x00 to 0xFE tenths of a second (only from 0x00
to 0x19 for internal beeper)
Response
OP 0x30
NA 0x0000
ARG None
Event
OP 0x30
NA 0x0002
ARG Byte 1: 0x00: Green LED
0x01: Red LED
0x02: external beeper
0x03: internal beeper
indicating that its timing has ended
Byte 2: always 0x00