For all the parameters described in the table, the configuration value corresponds to
the time in multiples of 10 ms that they are to remain enabled:
- With a correct reading for which CFG_Reader_BuzOK is enabled, the internal
buzzer (CFG_TempBuzz_OK) will be triggered.
- With an incorrect reading for which CFG_Reader_ BuzError is enabled, the inter-
nal buzzer (CFG_Temp-Buzz_Fail) will be triggered.
Permitted values:
- 0xFF: Permanently enabled.
- 0x01 .. 0xFE: Timing in multiples of 10 milliseconds.
- 0x00: Timing disabled.
Default value: depending on parameter (see table)
8.1.6. Others
Parameter$14: Display time-out. Time-out (in cycles) after writing on the Display.
Permitted values:
- 0xFF: legacy value. This is a very conservative Time-out.
- 0x0F: recommended value.
- 0x02: minimum value. Use it if no display is connected.
Default value:
- 0x0F: recommended value.
Table 10: Other configuration parameters
No. Description
Def.
$14
CFG-UI_DisplayTMO
Maximum time-out of the Display $0F