www.kimaldi.com Page 31 of 91
$0C Time-out in tenths of a second of the multiread fil-
tering, to detect that a card has left the reading
field.
See
Subsection 8.1.4.
$0D Configures the communications channel through
which the event frames are sent.
See
Subsection 8.1.2.
$0E FIM Boot-Up time
$0F Configure TTL_x ports as Wiegand Inputs
See
Subsection 8.1.4.
$10
a
$11
Reserved
$12 Host reply Time-Out, upon event generated by
BioMax2 / KBio2-Online, before switching to
Offline Mode
See
Subsection 5.5.
$13 No-traffic Time-Out, before switching to Offline
Mode
See
Subsection 5.5.
$14 Display response Time-Out
See
Subsection 8.1.6.
$15
to
$19
Reserved
$1A Determines the protocol and Baud Rate assigned
to the UART0. See Table 3 .
See
Subsection 8.1.1.
$1B Determines the protocol and Baud Rate assigned
to the UART1. See Table 3 .
See
Subsection 8.1.1.
$1C Determines the protocol and Baud Rate assigned
to the UART2. See Table 3 .
See
Subsection 8.1.1.
$1D Enables main FIM with Auto-On detection
See
Subsection 8.1.3.
$1E Enables auxiliary FIM with Auto-On detection
See
Subsection 8.1.3.
$1F Time, in tenths of a second, to indicate correct
reading with the green LED.
See
Subsection 8.1.5.
$20 Time, in tenths of a second, to indicate incorrect
reading with the red LED.
See
Subsection 8.1.5.
$21 Time, in tenths of a second, to indicate correct
reading with the buzzing of the external beeper.
See
Subsection 8.1.5.
$22 Time, in tenths of a second, to indicate incorrect
reading with the buzzing of the external beeper.
See
Subsection 8.1.5.
$23 Reserved for future uses.

Table of Contents