9.6.15. Write Display, Backlit
Function: It shows the specified text via the display in 2 rows of 20 characters. The
timing of the backlighting and the buzzer assembled in the BioMax2 / KBio2-Online
electronics are also specified.
9.6.16. Digital input status
Instruction
OP 0x14
NA 0x002A
ARG Byte 1: Backlit time (from 0x00 to 0xFE tenths of a sec.)
Byte 2: Timing of the internal buzzer (from 0x00 to 0x19 tenths)
Bytes 3 to 22: Text of the first row
Bytes 23 to 42: Text of the second row
Response
OP 0x14
NA 0x0000
ARG None
Instruction
OP 0x60
NA 0x0000
ARG None
Response
OP 0x60
NA 0x0001
ARG Bit 0: Status of DIN 0
Bit 1: Status of DIN 1
Bit 2: Status of DIN 2
Bit 3: Status of DIN 3