70
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
2: V/F control
A0.02
Main reference
frequency selector
0Digital setting
1AI1
2AI2
3AI3
4Set via DI terminal(PULSE)
5Reserved
1
0
0~5
A0.03
Set the operating
frequency in
digital mode
A0.11~A0.10
0.01Hz
50.00
0~30000
A0.04
Methods of
inputting operating
commands
0Panel control
1Terminal control
2Communication control
1
1
0~2
A0.05
Set running
direction
0Forward 1Reverse
1
0
0~1
A0.06
Acc time 1
0.0~6000.0
0.1S
2KW or
below:6.0S
30KW~45K
W:20.0S
45KW or
above:30.0S
0~60000
A0.07
Dec time 1
0.0~6000.0
0.1S
2KW or
below:6.0S
30KW~45K
W:20.0S
45KW or
above:30.0S
0~60000
A0.08
Max. output
frequency
upper limit of frequency A0.11~
300.00Hz
0.01Hz
50.00
×
0~30000
A0.09
Max. output
voltage
0~480
1V
VFD’s rated
values
×
0~480
A0.10
Upper limit of
frequency
A0.12~A0.08
0.01Hz
50.00
0~30000
A0.11
Lower limit of
frequency
0.00~A0.11
0.01Hz
0.00
0~30000
A0.12
Basic operating
0.00~Max.output frequency
0.01Hz
50.00
0~30000