EasyManuals Logo

Kinco SV100 Series User Manual

Kinco SV100 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
70
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
2: V/F control
A0.02
Main reference
frequency selector
0Digital setting
1AI1
2AI2
3AI3
4Set via DI terminal(PULSE)
5Reserved
1
0
0~5
A0.03
Set the operating
frequency in
digital mode
A0.11~A0.10
0.01Hz
50.00
0~30000
A0.04
Methods of
inputting operating
commands
0Panel control
1Terminal control
2Communication control
1
1
0~2
A0.05
Set running
direction
0Forward 1Reverse
1
0
0~1
A0.06
Acc time 1
0.0~6000.0
0.1S
2KW or
below:6.0S
30KW~45K
W:20.0S
45KW or
above:30.0S
0~60000
A0.07
Dec time 1
0.0~6000.0
0.1S
2KW or
below:6.0S
30KW~45K
W:20.0S
45KW or
above:30.0S
0~60000
A0.08
Max. output
frequency
upper limit of frequency A0.11~
300.00Hz
0.01Hz
50.00
×
0~30000
A0.09
Max. output
voltage
0~480
1V
VFD’s rated
values
×
0~480
A0.10
Upper limit of
frequency
A0.12~A0.08
0.01Hz
50.00
0~30000
A0.11
Lower limit of
frequency
0.00~A0.11
0.01Hz
0.00
0~30000
A0.12
Basic operating
0.00~Max.output frequency
0.01Hz
50.00
0~30000

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinco SV100 Series and is the answer not in the manual?

Kinco SV100 Series Specifications

General IconGeneral
BrandKinco
ModelSV100 Series
CategoryDC Drives
LanguageEnglish

Related product manuals