EasyManua.ls Logo

Kioti CK2810 - Checking Radiator Hose and Clamp (Z)

Kioti CK2810
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
57
7
-
27
M56O724A
Check to ensure the radiator hoses
are free from damage and are tight-
ened properly every 200 hours or ev-
ery 6 months, whichever comes rst.
(1) Clamp (2) Hose

PRECAUTION AT OVERHEATING
Take the following actions in the
event the coolant temperature reach-
es the boiling point, what is called
"Over-heating".
1. Stop the machine in a safe place
and keep the engine idling.
2. After 5 minutes of unloaded idling,
shut the engine down.
3. Keep yourself away from the trac-
tor for another 10 minutes or until
steam has stopped blowing out of
the engine.
4. Make sure that there is not danger
and repair the cause of the over-
heating according to the manual’s
instruction.
1. If the hose clamps are loose or
water leaks from hose, tighten
clamps securely.
2. If the radiator hoses are swollen,
hardened, cracked, or otherwise
damaged, you must replace the
hoses. Failure to do so could lead
to coolant loss and engine damage.
M56(TB110)(CK2810)-호주판-OM-07.ind27 27 2012-10-16 오후 2:47:31

Table of Contents