M56O719A
its function if it is correctly
and regularly maintained. A
-
a reduction in engine life.
-
ter element removed.
•
•
IMPORTANT
(1) Filter (2) Cap
(3) Evacuator Valve
1. The air cleaner uses a dry ele-
ment. Never apply oil.
2. Dust should not accumulate in the
dust cap or element. Remove and
clean the dust cap and the ele-
ment every week. If the tractor is
operated in extremely dusty condi-
tions, daily inspection is required.
3. When cleaning the element, refer
to the instructions that follow.
arrow
⬆
function and dust will adhere
to the element.
•
IMPORTANT
EVACUATOR VALVE
Open the evacuator valve gap by
fingers once a week under ordinary
conditions or daily when used in dusty
conditions to get rid of large particles
of dust and dirt.
4. The lter should be replaced every
year or after cleaning for 6 times,
whichever comes rst.
To clean the element, use only clean
dry compressed air on the inside of
the element. Air pressure at the nozzle
must not exceed 29 psi (2 kgf/cm²).
Maintain reasonable distance be-
tween the nozzle and the lter.