Section 10
Specifications
20479304
2-2012/Rev 04
10-3
Cutting Water Supply (Low Pressure Water System)
Booster pump factory set outlet pressure 120 psi (8.3 bar)
Optimum inlet water temperature
65 F (18 C)
Maximum inlet water temperature
85 F (29 C)
Booster pump overheat
128 F (53 C)
Recirculation System
Maximum consumption at 75 F (24 C) (oil-to-water models)
3.0 gpm (11.4 L/min)
Total heat rejection 8.6 HP (6.4 kW)
Reservoir capacity 40 gal (151 L)
Low oil level shutdown 30 gal (114 L)
Minimum operating oil temperature
60 F (15 C)
Optimum operating oil temperature
115 F (46 C)
Hot oil shutdown (maximum operating oil temperature)
144 F (62 C)
Minimum inlet cooling water pressure (oil-to-water models) 35 psi (2.4 bar)
Maximum inlet cooling water pressure (oil-to-water models) 100 psi (6.9 bar)
Oil filtration rating (Beta filtration rating)
Β
7
1000*
Fluid cleanliness rating (ISO fluid cleanliness rating)) 17/14**
Nominal recirculation pressure 30 psi (2 bar)
Recommended oil type
General service Mobil DTE 26, Grade 68
Conoco Hydroclear
TM
multi-purpose
R&O
Food service Fuchs/Geralyn AW68
* Note: For each particle per milliliter downstream of the filter greater than 7 microns, there are 1000
particles per milliliter larger than 7 microns upstream of the filter.
**Note: Indicates ISO 4406 range numbers for maximum permissible number of particles per milliliter,
greater than 5 and 15 microns.
17 <1,300 particles per milliliter, >5 microns
14 <160 particles per milliliter, >15 microns