Existing conditions aggravated by
exposure:
Eye, skin, and respiratory disorders.
See Section 11 for additional toxicological information.
4. FIRST AID MEASURES
Inhalation: Remove to fresh air. If symptoms develop and persist, get medical attention.
Skin contact: Wash with soap and water. Remove contaminated clothing and shoes. Wash clothing before reuse.
Get medical attention if symptoms occur.
Eye contact: Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding
eyelids open all the time. Get medical attention.
Ingestion: Do not induce vomiting. Keep individual calm. Obtain medical attention.
5. FIRE-FIGHTING MEASURES
Flash point: Greater than 93ºC (200ºF) Tagliabue closed cup
Autoignition temperature: Not available
Flammable/Explosive limits-lower %: 2.6 % (propylene glycol)
Flammable/Explosive limits-upper %: 12.5 % (propylene glycol)
Extinguishing media: Foam, dry chemical or carbon dioxide.
Special fire fighting procedures: None
Unusual fire or explosion hazards: None
Hazardous combustion products: Oxides of carbon. Oxides of sulfur. Oxides of nitrogen. Irritating organic vapors.
6. ACCIDENTAL RELEASE MEASURES
Environmental precautions: Prevent product from entering drains or open waters.
Clean-up methods: Soak up with inert absorbent. Store in a partly filled, closed container until disposal.
7. HANDLING AND STORAGE
Handling: Avoid contact with eyes, skin and clothing. Avoid breathing vapor and mist. Wash thoroughly after
handling.
Storage: For safe storage, store at or below 38°C (100°F). Keep in a cool, well ventilated area away from heat,
sparks and open flame. Keep container tightly closed until ready for use.
Incompatible products: Refer to Section 10.
For information on product shelf life contact Henkel Customer Service at (800) 243-4874.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering controls: No specific ventilation requirements noted, but forced ventilation may still be required if concentrations
exceed occupational exposure limts.
2 of 5
24231Item No. :
Product name: 242 Threadlocker

Table of Contents