4. FIRST AID MEASURES
Inhalation: Remove to fresh air. If discomfort persists seek medical attention.
Skin contact: Wash with soap and water.
Eye contact: Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding
eyelids open all the time.
Ingestion: If conscious, drink plenty of water. Do not induce vomiting. Keep individual calm. Obtain medical
attention.
5. FIRE-FIGHTING MEASURES
Flash point: -20°C (-4°F) (estimated)
Autoignition temperature: 465°C (869°F)
Flammable/Explosive limits-lower %: 2.6 %
Flammable/Explosive limits-upper %: 13 %
Extinguishing media: Foam, dry chemical or carbon dioxide.
Special fire fighting procedures: None
Unusual fire or explosion hazards: Vapors may accumulate in low or confined areas, travel considerable distance to source of ignition,
and flash back.
Hazardous combustion products: Oxides of carbon. Oxides of nitrogen. Irritating organic vapors.
6. ACCIDENTAL RELEASE MEASURES
Environmental precautions: Prevent product from entering drains or open waters.
Clean-up methods: Remove all ignition sources. Ensure adequate ventilation. Soak up with inert absorbent. Store in a
closed container until ready for disposal.
7. HANDLING AND STORAGE
Handling: Avoid contact with eyes, skin and clothing. Avoid breathing vapor and mist. Wash thoroughly after
handling. During use and until all vapors are gone: Keep area ventilated - do not smoke; extinguish all
flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources
of ignition.
Storage: Store away from heat, sparks, flames, or other sources of ignition. For safe storage, store at or below
49°C (120°F).
Incompatible products: Refer to Section 10.
For information on product shelf life contact Henkel Customer Service at (800) 243-4874.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering controls: Use local ventilation if general ventilation is insufficient to maintain vapor concentration below
established exposure limits.
Respiratory protection: Use NIOSH approved respirator if there is potential to exceed exposure limit(s).