SECTION 3
OPERATION
p. 3-6
05146410
Run Screen ALARMS
1. High Oil temperature
– Indicates high hydraulic oil temperature-150º F.
2. High Pressure Warning
– Indicates that output pressure is above 64,000
psi or 4,413 BAR.
3. Booster Temperature High
– Indicates booster pump water temperature
is high and machine shutdown is pending-128º F.
4. Low Booster Pressure
– Indicates that booster pump output pressure is
inadequate for proper machine operation and shutdown is pending, less
than 60psi.
5. Low Inlet Water Pressure
– indicates that cutting supply water pressure
is inadequate to permit proper machine operation and shutdown is
pending, less than 30psi.
6. Bleed High Pressure Lines
– Indicates that the intensifier is shut down
and that high pressure is present in the discharge plumbing of the
intensifier that should be bled off to avoid the possibility of injury.
7. Left/Right/Intensifier Overstroke Warning and Shutdown Pending
Indicates an abnormally high stroke rate caused by an external or
internal leak. If the condition persists, the machine will be shut down
with an Overstroke Shutdown alarm.
8. Reset Inlet Water
- Indicates inlet water must be reset. RESET will
flash and can be reset by pressing stop button

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KMT STREAMLINE SL-IV 50 PLUS and is the answer not in the manual?

KMT STREAMLINE SL-IV 50 PLUS Specifications

General IconGeneral
BrandKMT
ModelSTREAMLINE SL-IV 50 PLUS
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals