KONE UniDrive
TM
service manual vs 9 50
2.8. Default settings
Nr Function Setting ‘Default’ Remarks
1 PGS selection Open
2 Winter selection Off
3 Airlock selection Off
4 Open speed 80% On UWSPGS ‘8’
5 Closing speed 40% On UWSPGS ‘4’
6 Obstacle sense open Normal
7 Obstacle sense close Normal
8 Power Open 100%
9 Power Close 100%
10 Winter position 75% On UWSPGS ‘7’
11 Open timer 1 sec
12 Winter timer 20 sec
13 Airlock timer 20 sec
14 User timer 10 sec
15 Lock delay timer 0 %
16 Toilet mode Off
17 Power fail action Open * *
Only when battery is adapted
18 Battery empty action Close * *
Only when battery is adapted
19 Battery Empty signal Take Action
20 Battery test interval timer 24 hours
21 Discard power fail action
when PGS closed
On
22 Motor type
KONE UniDrive
TM
23 Service Interval 125000 (flashing)
24 Overload Service Interval 2500 (continuous on) Service timer off
25 Easy come in On
26 Ext. lock type default
27 Lock type Monostable Dipswitch 1 = off
28 Lock version Powerless locked Dipswitch 2 = off
29 Left/Right open Right Dipswitch 3 = off
30 One way with locking Off Dipswitch 4 = off
31 Hermetically mode Off Dipswitch 5 = off
32 Spring cord Off Dipswitch 6 = off
33 Door leaves Double Dipswitch 7 = off
34 NS input NS mode (Timer mode) Dipswitch 8 = off
35 Input 1 Stop NO PGS close priority
36 Input 2 Open NO
37 Input 3 One way NO
38 Input 4 Close and locked
39 Input 5 Inactive
40 Input 6 Inactive
41 Input 7 Inactive
42 Input 8 Inactive
43 Output 1 Indication “closed” NC
44 Output 2 Inactive ;Normal; NP
45 Output 3 Inactive ;Normal; NP
46 Output 4 Inactive ;Normal; NP
47 Output 5 Inactive ;Normal; NP