service manual vs 9 56
2.12. Changed functions in UniDrive software V1.35:
1. Opening the door on a bungee cord at power failure is changed.
When a bungee cord is programmed and a power-fail is detected, the door now tries to open on the power that is still left within the
internal power supply.
2. Memory testing changed.
Internal tests of memory is changed to fulfill national and European regulations. No influence on door behaviour.
3. Motor power control and maximal pressing force.
Power control of connected motor is changed to limit the maximal static force, to fulfill the European regulations on static limits at
the doorwings of 150N.
4. Airlock function, faster release of output.
When the door is used in an airlock and both doors are closed, the release of the airlock output is faster to avoid long waiting time
before the other door in an airlock opens.
5. UniDrive PGS, showing when overruled by an input.
When the PGS is overruled by a programmable input, the PGS shows the status of the activated input. The LED’s on the PGS will
blink for a short moment to indicate that an other function is active. The PGS is blocked until the activated input is no longer
active.
6. Immediate storing of programmed settings.
When a setting or programmed function is changed by use of Psion programmer, the changed function or setting is directly stored
in internal memory. This should avoid the problem that sometimes functions are not stored when programmed by Psion. When
settings are stored, a short beep will be heard.