KONE UniDrive
TM
service manual vs 9 9
1.3.2. Open commands: Inside and outside
Total power consummation of all external connections / users is maximum 800mA (exc. locking device)
Select 12 or 24 V dc with jumper 12/24 on the connection terminal (see page 5)
1.3.3. Photocells
Test 12/24V
Out 2 1N4002
Ground
Out 1
+ 12/24V
1.3.3.1. Connection without photocells / sensors
In according to DIN18650 and Pren 12650, diodes must be connected when no photocells /sensors are used.
N.O .
Inside Inside
O utside Outside
+ 24V dc + 24Vdc
+ 24V dc + 24Vdc
OUTSIDE
IN SID E
+
N.O .
+
Test +24 V Transmitter
Ground
Ground Receiver
Out
+ 24
VDC
+12/24Vdc
+12/24Vdc
+12/24Vdc
+12/24Vdc