OTHER KINDS OF CONTROL
2-P-12
2 UNIT EXPLANATION
<Functions and output timings of signals for copy vendors>
Connector Pin No. Signal name Description Output timing Signal type
35
1
DV24V Key counter power supply Always 24 V, 300 mA
2
C(K) SIG Key counter connection rec-
ognition
--
3
C(K) GND Signal ground
4
C(K) DRIVE Key counter signal count up 100-ms L-signal output
after paper ejection
-
5
P. GND Power ground
--
36
1
Vendor Copy Copying signal Output from the moment
START PRINT button is
pressed to the moment
paper ejection is com-
pleted.
Open collector
5V, 200 mA
2
Vendor FEED Paper feed signal Common to main body
tray. 100-ms L-signal
output in sync with paper
feed.
3
Paper size 0 Paper size signal Output when paper size
is changed.
4
Paper size 1
5
Paper size 2
6
Paper size 3
7
Vendor
screen
Double-sided copy selec-
tion signal
Output when ADU mode
is selected.
8
CPF SIG0 CPF mode selection signal Output when copy or
printer mode is selected.
9
CPF SIG1
10
P. GND Power ground
--
2-P-10