Arp & Setup page
50
Rx Other CCs
[O, On]
On: is is the default. e Layer will respond normally to MIDI CCs.
O: e Layer will ignore all MIDI CCs (except for CC#64), as well as Aertouch, Poly Aertouch, and Pitch Bend.
Program Setup
Volume
[-Inf, -84.9…0.0 dB]
is controls the overall volume of the Program, for volume-balancing with other sounds.
Transpose
[-60…+60 semitones]
is transposes the Program by up to +/- ve octaves, in semitones.
Random Pitch Range
[0.0…50.0 cents]
is parameter creates random variations in pitch for each note. At the default of 0.0, pitch will be completely stable;
higher values create more randomization. is can be helpful for simulating instruments that have natural pitch
instabilities, such as analog synths, tape-loop keyboards, or acoustic instruments.
Trigger
Trigger On
[Key-On, Key-O]
Key-On: is is the default setting, in which the Program is played when a key is pressed.
Key-O: e Program will play as soon as you release the key. You can use this to create the “click” heard when a
harpsichord note is released, for instance. In general, when using Key-O its also best to set the Amp Envelope Sustain
to 0.
Voice Allocation
Mode = Poly
(Voice Assign) Mode
[Poly, Mono]
is selects the basic voice allocation mode. Depending on which one you select, various other options will appear,
such as Single Trig (Poly mode only) and Mono Legato and Priority (Mono mode only).
Poly: e Program will play polyphonically, allowing you play chords.
Mono: e Program will play monophonically, producing only one note at a time.
Single Trigger
[O, On]
Single Trigger is available when Voice Assign Mode is set to Poly.
On: When you play the same note repeatedly, the previous note will be silenced before the next note is sounded, so that
the two do not overlap.
O: When you play the same note repeatedly, the notes will overlap.
Max # of Notes
[Dynamic, 1…32]
Max # of Notes is available when Voice Assign Mode is set to Poly.
Dynamic is the default. With this setting, you can play as many notes as the system allows.
1-64 limits the number of notes played by the Program. Voices will be allocated dynamically up to this maximum. You
can use this to:

Questions and Answers: