Enable Program Change
This species whether or not MIDI Program Change messages will be transmitted and received.
If this is
checked
, Program Change messages will be transmitted and received. However, the
Enable Bank Change and Enable Combination Change settings will apply.
In Program Play mode, programs will be selected by incoming Program Change messages on a
channel that matches the Global MIDI channel.
When you select a program, a Program Change message will be transmitted on the Global MIDI
channel.
In Combination Play mode, combinations will be selected by incoming Program Change messages
on a channel that matches the Global MIDI channel. However this can be disabled by the Enable
Combination Change setting.
Incoming Program Change messages whose channel matches the channel settings of Combination
Edit mode 11e: MIDI Channel (
page 58 in this manual) will select programs for that timbre.
When you select a combination, a Program Change message will be transmitted on the Global
MIDI channel, and also simultaneously transmitted on the channel of each timbre whose Combi-
nation Edit mode 11d: Timbre Mode parameter (
page 58 in this manual) is set to EXT.
In Sequencer mode, incoming Program Change messages on a channel that matches the channel
setting of a track whose Track Status is INT or BOTH will select programs for that track.
When you select a song or playback a sequence, Program Change messages will be transmitted on
the channel specied for each track whose Track Status is EXT or BOTH.
If Enable Bank Change is checked, Bank Select messages will be transmitted together with Pro-
gram Change messages.
If Enable Program Change is
un-checked
, Program Change messages will be neither transmit-
ted nor received.
Enable Bank Change
This species whether MIDI Bank Select messages will be transmitted and received.
If this is
checked
, both Bank Select and Program Change messages will be transmitted and
received if Enable Program Change is checked.
If this is
un-checked
, only Program Change messages will be transmitted or received if Enable
Program Change is checked.
When recording to the sequencer, Bank Select messages will be recorded regardless of this set-
ting, but playback will be affected by this setting.
21a
21b
Page Menu
21A
21B
21C
21D
21E
21F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Korg Trinity V3 and is the answer not in the manual?

Korg Trinity V3 Specifications

General IconGeneral
BrandKorg
ModelTrinity V3
CategoryRecording Equipment
LanguageEnglish

Related product manuals