EasyManuals Logo

Korg Triton Studio User Manual

Korg Triton Studio
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
126
For each track, you can specify the status of the internal tone
generator and the scale.
11: Status 18 (Status/Scale T0108)
12: Status 916 (Status/Scale T 0916)
11(2)a: Status
Status [INT, Off, BTH, EXT]
Species whether each track will transmit/receive MIDI
data and/or sound the internal tone generator.
INT: When you playback the musical data of this track, or
operate the TRITON STUDIOs keyboard or controllers
when Play (Track Select) (01g) is set to a track whose set-
ting is INT, the TRITON STUDIOs internal tone generator
will sound, but MIDI messages will not be transmitted to
external devices.
Off: The program will not sound, nor will MIDI messages
be transmitted.
BTH: The operations of both INT and EXT will occur. When
you play the musical data of this track, or operate the TRI-
TON STUDIOs keyboard or controllers when Play (Track
Select) is set to a track whose setting is BTH, the TRITON
STUDIOs internal tone generator will sound, and MIDI
messages will also be transmitted to external devices.
EXT: When you playback the musical of this track, or oper-
ate the TRITON STUDIOs keyboard or controllers when
Play (Track Select) is set to a track whose setting is EXT,
MIDI messages will be transmitted to external devices, but
the TRITON STUDIOs internal tone generator will not
sound.
11(2)b: Use Programs Scale/Scale
Use Programs Scale [Off, On]
For each track you can specify whether or not the scale spec-
ied for the program in Scale (Program P1: 11c) will be
used.
On (checked): The scale specied by the program will be
used.
Off (unchecked): The scale specied by Scale (11b/2b)
will be used.
Scale:
Select the scale that will be used in Song Play mode.
Type [Equal Temperament...User Octave Scale15]
Selects the scale type (Type Program P1: 11c).
Key (Scale Key) [CB]
Selects the tonic key of the selected scale (Key Program
P1: 11c).
Random [07]
As this value is raised, an increasing amount of random
deviation will be applied to the pitch at note-on (Ran-
dom Program P1: 11c).
13: MOSS 18 (MOSS Setup T0108)
14: MOSS 916 (MOSS Setup T0916)
This page is displayed only when the EXB-MOSS option has
been installed.
For details refer to the EXB-MOSS owners manual.
Song Play P1: Track
Musical data
Keyboard and controller
operations Received data
Status Internal tone
generator
MIDI OUT Internal tone
generator
MIDI OUT
INT ●✕●
EXT ✕●✕
BTH ●●●
01a
01b
03a
01
11a
11b

Table of Contents

Other manuals for Korg Triton Studio

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Korg Triton Studio and is the answer not in the manual?

Korg Triton Studio Specifications

General IconGeneral
MIDIIn, Out, Thru
TypeWorkstation
Polyphony62 voices
Oscillators2 oscillators per voice
Effects2 master effects
Sequencer16-track
Sampling16-bit, 48 kHz, expandable RAM (optional EXB-SMPL board)
DisplayTouchView graphical interface
StorageInternal hard drive, floppy disk drive
Keyboard61, 76, or 88 keys with velocity and aftertouch
Sound ROM32 MB (expandable with EXB series)
Outputsstereo main outputs
InputsL/Mono, R

Related product manuals