TROUBLESHOOTING
kortho Hot Quick Coder-D H215 AE Rev.: 10
7-2
7.3 Error 003
Occursonlyatsystemboot.
7.3.1 -20°C
Fig. 7.4 ERROR003,‐20°C.
ThetemperaturesensorcircuitisshortcircuitedorthePT1000sensorisdefect.
7.3.2 300°C
Fig. 7.5 ERROR003,300°C.
Thetemperaturesensorcircuitisopencircuited,thePT1000sensorisnotconnectedordefectandifan
HQCATheatingelement/codingunitisconnectedtothecontrolbox.
7.4 Error 004
OccursonlyiftheSETALARMparameterisset.
Fig. 7.6 ERROR004.
Thetemperaturealarmisactivated.
AtoohighortoolowprinttemperaturedeviationfromtheSETTEMPparametervalue(±5°C,±10°Cor
±15°C)hasoccured.
Theactualprinttemperatureisdisplayed,hererepresentedas###°C.
ERROR 003
-
20…C
ERROR 003 300…C
ERROR 004 ###…C