Page #67 background imageLoading...
Page #67 background image
TTD-EF2_EN.xls 07.06.2011 Page 2 of 2
Type
EF2 S / EF2 GS / EF2 V 8 121522253035
Emissions according to test report FJBLT FJBLT FJBLT FJBLT FJBLT FJBLT FJBLT
Test report no. BLT-018/10 BLT-019/10 ** BLT-020/10 ** ** BLT-021/10
O
2
content rated power
Vol.-% 7,7 9,2 8,6 7,3 7,0 6,6 6,1
O
2
content partial load
Vol.-% 12,4 9,7 9,9 10,3 10,4 10,7 10,9
CO
2
content rated power
Vol.-% 12,8 11,4 11,9 13,2 13,4 13,9 14,4
CO
2
content partial load
Vol.-% 8,2 10,9 10,7 10,3 10,2 9,9 9,7
CO at rated power mg/Nm³ 11,0 33,0 27,6 15,0 13,8 11,9 10,0
CO at partial load mg/Nm³ 153,0 20,0 21,5 25,0 25,7 26,8 28,0
NOx at rated power mg/Nm³ 148,0 135,0 137,7 144,0 147,5 153,2 159,0
NOx at partial load mg/Nm³ 126,0 131,0 131,0 131,0 133,3 137,2 141,0
OGC at rated power mg/Nm³ <1 <1 <1 <1 <1 <1 <1
OGC at partial load mg/Nm³ <1 <1 <1 <1 <1 <1 <1
Dust at rated power mg/Nm³ 14,0 21,0 16,8 7,0 8,4 10,7 13,0
Dust at partial load mg/Nm³ 7,0 9,0 11,7 18,0 15,9 12,5 9,0
Reference 13 % O
2
dry (FJ-BLT)
CO at rated power mg/Nm³ 8,0 24,0 20,1 11,0 10,1 8,5 7,0
CO at partial load mg/Nm³ 111,0 15,0 15,9 18,0 18,5 19,2 20,0
NOx at rated power mg/Nm³ 108,0 98,0 100,1 105,0 107,3 111,2 115,0
NOx at partial load mg/Nm³ 91,0 96,0 95,7 95,0 96,8 99,9 103,0
OGC at rated power mg/Nm³ <1 <1 <1 <1 <1 <1 <1
OGC at partial load mg/Nm³ <1 <1 <1 <1 <1 <1 <1
Dust at rated power mg/Nm³ 10,0 15,0 12,0 5,0 6,2 8,1 10,0
Dust at partial load mg/Nm³ 5,0 7,0 8,8 13,0 11,4 8,7 6,0
CO at rated power mg/MJ 5,0 15,0 12,6 7,0 6,3 5,2 4,0
CO at partial load mg/MJ 71,0 9,0 9,9 12,0 12,2 12,6 13,0
NOx at rated power mg/MJ 68,0 63,0 64,2 67,0 68,4 70,7 73,0
NOx at partial load mg/MJ 58,0 61,0 61,0 61,0 61,9 63,5 65,0
OGC at rated power mg/MJ <1 <1 <1 <1 <1 <1 <1
OGC at partial load mg/MJ <1 <1 <1 <1 <1 <1 <1
Dust at rated power mg/MJ 6,0 10,0 7,9 3,0 3,7 4,8 6,0
Dust at partial load mg/MJ 3,0 4,0 5,2 8,0 7,1 5,5 4,0
mg/Nm³ Milligram per standard cubic meter (1 Nm³ under 1.013 hectopascal at 0 °C)
** Drawing inspection, values for intermediate sizes interpolated
FJ - BLT Franciso Josephinum Wieselburg Biomass Logistic Technology
Reference 10% O
2
dry (EN303-5)
In accordance with §15a-BVG Austria

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW
Hopper capacity15 kg
Flue diameter130 mm