2K3/2L3
1-5-15
(4) Detaching and refitting the registration cleaner
Procedure
1. Open the right cover 1.
(See page 1-5-11)
2. Open the front cover. (See page 1-5-3)
3. Open the developing cover.
(See page 1-5-17)
4. Set the cleaner lever (yellow) up and
draw the registration cleaner frontward.
5. Check or replace the registration
cleaner and refit all the removed parts.
Figure 1-5-24
(5) Detaching and refitting the MP tray
Procedure
1. Open the MP tray.
2. Release two fulcrums of the MP tray by
using a flat screwdriver.
3. Pull two straps upwards to remove.
4. Remove the MP tray.
Figure 1-5-25
q
Regist cleaner
Cleaner lever(yellow)
Flat screwdriver
Fulcrum
MP tray
Straps
Fulcrum
Flat screwdriver