1-6 Requi rements on P WB Replacement
1-6-1 Upgrading the firmware
Follow the procedure to upgrade the firmware below.
Preparation
Extract the file that has the download firmware and put them in the USB Memory.
NOTE: To improve Firmware Upgrade speed, a separate SKIP file can be added to the USB Memory Stick
with the Firmware Upgrade package. The Skip file will allow ONLY the Firmware that has been
Upgraded to a New Version to load, skipping duplicate Firmware Levels.
Procedure
1. Turn ON the main power switch and
confirm if the screen shows “Ready to
print” then, turn OFF the main power
switch.
2. Insert USB memory that has the firm-
ware in the USB memory slot.
3. Turn ON the main power switch.
4. About 50 seconds later, “Farmware
Update” will be displayed (this shows to
start the download).
5. Display the software that now upgrad-
ing.
CTRL DP PF DF AK IO
ENGN FAX OPT DIC
PANL
Figure 1-6-1
SAMPLE:
=================
Firmware Update The first line: Display shown while updating it
CTRL The second line: Display that shows update object
xxx% The third line: The progress of the update is displayed with %.
=================
6. Display the completion of the upgrade.
7. ROM version is confirmed by the con-
tent of the display.
8. Turn OFF the main power switch and
remove the USB memory.
USB memory
USB memory slot
* Main PWB (CTRL)
* DP main PWB (DP)
* PF main PWB (PF)
* DF main PWB (DF)
* Bridge PWB (AK)
* Engine IO PWB (IO)
* Engine PWB (ENGN)
* FAX PWB (FAX)
* Language data (OPT)
* Dictionary data (DIC)
* Operation panel PWB (PANL)