Maintenance
Description
item No.
2DF
1-4-30
U161 Setting the fixing correct temperature
1. Select the item to be set. The selecting item is displayed in reverse.
2. Change the setting using the cursor up/down keys.
Display Description Setting range Initial setting
COPY UP TEMP(L) Fixing correct temperature -30 to +30 (°C) 5
for large size copying
COPY UP TEMP(M) Fixing correct temperature -30 to +30 (°C) 2
for middle size copying
COPY UP TEMP(S) Fixing correct temperature -30 to +30 (°C) 0
for small size copying
L/L UP TEMP Fixing temperature increase amount 0 to +20 (°C) 5
at low temperature and low humidity
H/H DOWN TEMP Fixing temperature decrease amount 0 to +20 (°C) 5
at high temperature and high humidity
DUP DOWN TEMP Fixing temperature decrease amount 0 to +20 (°C) 5
for duplex copying
3. Press the start key. The value is set.
Interrrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U162 Stabilizing fixing forcibly
Description
Stops the stabilization fixing drive forcibly, regardless of fixing temperature.
Purpose
To forcibly stabilize the machine before the fixing section reaches stabilization temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regardless
of fixing temperature. The screen for selecting a maintenance item No. is displayed.
To exit the forced stabilization mode, turn the power off and on.
Completion
To exit this maintenance item without executing forced fixing stabilization, press the stop/clear key.The screen
for selecting a maintenance item No. is displayed.
U163 Resetting the fixing problem data
Description
Resets the detection of a service call code indicating a problem in the fixing section.
Purpose
To prevent accidents due to an abnormally high fixing temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press CANCEL on the touch panel.
3. Press the start key. The fixing problem data is initialized.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.