A B C D E F G H I J
A B C D E F G H IJ
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
General wiring diagram
2DF
2-4-20
C32-2 BE
C32-1 RD
C119
2
1
24V
PG
C55(CN44)
C32(CN45)
C119-1
C119-2
1
2
PG-
24V
C107
C62
C72
C77
C61
C112
C111
RESERVE
14
PD
GND
R24V
GND
SCAN
SCRDYN
SCCLK
5V SAFE
SAMPLE
POWCONT
LASER
VDO+
VDO-
GND
10
11
12
13
6
7
8
9
5
4
3
2
1
C18-1 OE
C18-2 BE
C18-3 YW
C18-4 BE
C18-5 LB
C115-1 PE
C115-2 BE
C116
9
8
7
6
5
4
3
2
1
FFC
C70
C67
C68
C69
C66
C65
C18
C115
C116-9 BE
C116-8 PE
C116-7 LB
C116-6 BE
C116-5 YW
C116-3 BE
C116-1 OE
C110
C109
C57
C56
C53
C54
C71
C51
C114
C108
C52
C11
C100
C97
C98
1
2
3
4
C1-1 RD
C10-1 RD
C3-3 RD
C3-2 RD
C3-1 RD
C3-8 BE
C3-7 BE
C3-6 BE
C3-5 BE
C3-4 RD
C89
C88
C94
C95
C90
C92
C91
C93
C99
C106
C107
C105
C101
C31-10 GY
C31-9 YW
C31-15 YW
C31-14 GY
C31-13 YW
C31-12 GY
C31-11 YW
C31-2 YW
C31-1 GY
C31-8 GY
C31-7 YW
C31-6 GY
C31-5 GY
C31-4 YW
C31-3 GY
5V
12V
EVEN
GND
ODD
GND
RS-
GND
CLP
GND
SHIFT
GND
CLK-
CLK+
RS+
1
15
14
13
12
11
10
9
8
7
6
5
4
3
2
11
GND
C105-5 YW
C59
C3-10
C3-9
C24-2
C24-1
C23-4 BE
C23-3 WE
C23-2 BE
C23-1 RD
C36-9 GY
C36-10 GY
C36-11 GY
C36-12 GY
C36-8 GY
C36-7 GY
C36-6 GY
C36-5 GY
C36-4 GY
C36-3 GY
C36-2 GY
C36-1 GY
C35-1 RD
C35-2 BE
C35-3 BE
C35-4 YW
C35-6 GN
C35-7 GY
C35-8 RD
C35-10 RD
C35-9 WE
C35-12 GN
C35-11 WE
C29-B5 YW
C29-B3 YW
C29-B4 YW
C29-B1 YW
C29-B2 YW
C29-B6 YW
C29-B7 YW
C29-B8 YW
C29-B9 YW
C97-2 GY
C97-1 GY
C97-4 GY
C97-3 GY
C97-6 GY
C97-5 GY
C97-8 GY
C97-7 GY
C97-10 GY
C97-9 GY
C97-12 GY
C97-11 GY
C98-2 BE
C98-1 RD
C98-4 YW
C98-3 BE
C98-6 GN
C98-5 BN
C98-8 RD
C98-7 GY
C98-10 RD
C98-9 WE
C98-12 GN
C98-11 WE
C40-12 WE
C40-13 WE
C40-14 WE
C40-10 WE
C40-11 WE
C40-8 WE
C40-9 WE
C40-6 WE
C40-7 WE
C40-4 WE
C40-5 WE
C40-2 WE
C40-3 WE
C100-3 WE
C40-1 WE
C100-1 WE
C100-2 WE
C105-2 GY
C105-1 YW
C105-4 GY
C105-3 YW
C105-6 GY
C105-7 YW
C105-8 GY
C105-9 YW
C105-10 GY
C105-11 GY
C105-12 YW
C104-13 GY
C105-14 YW
C101-15 GY
C103-1 YW
C103-3 YW
C103-2 YW
C107-2 YW
C107-1 YW
C106-2 YW
C106-1 YW
C105-2 YW
C105-1 YW
C105-4 YW
C105-3 YW
C105-5 YW
GND
GND
GND
GND
N.C
F1 24V
F1 24V
F1 24V
F1 24V
F3 5V
GND
RXD
SET SIG
RESET
GND
TXD
GND
C46-A8 WE
C46-A7 WE
C46-A6 WE
C46-A5 WE
C46-A4 WE
C109-2
C109-2 RD
C110-1
C110-2 RD
C16
C14-2 PE
C14-1 RD
MSW OFF REM
24V
C14-5
C14-6
C14-3
C14-4
24V
TC2 REM
24V
TC REM
C15
C14-7 BE
C14-8 YW
C14-9 RD
C14-10 LB
GND
SET SIG
24V
K.COUNT REM
C102
C103
C104
C104-2 WE
C104-1 WE
C104-8 WE
C104-3 WE
C104-4 WE
C104-7 WE
C104-6 WE
C104-5 WE
C104-9 WE
C104-10 WE
C104-11 WE
C73
C74
C75
C87
C86
C85
C96
C84
C80
C79
C78
C76
C83
C82
C81
C7-1 BK
C22-B6 GN
C3-11 OE
C3-12 BE
C3-13 BE
C3-14 RD
C3-15 RD
C3-16 RD
C3-17 OE
C3-18 BE
C3-19 BE
C3-20 BE
C7-3 WE
C22-B5 YW
C22-B4 BE
C22-B3 RD
C22-B2 BE
C22-B1 WE
C22-A6 PK
C22-A5 BN
C22-A4 BE
C22-A3 WE
C22-A2 BE
C22-A1 RD
C7-1 BK
C7-3 WE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
C28-14 WE
C28-13 WE
C28-12 WE
C28-11 WE
C28-10 WE
C28-9 WE
C28-8 WE
C28-7 WE
C28-6 WE
C28-5 WE
C28-4 WE
C28-3 WE
C28-2 WE
c28-1 WE
C25-1 GY
C25-2 GY
C25-3 GY
C25-4 GY
C25-5 GY
C25-6 GY
C25-7 GY
C25-8 GY
C25-9 GY
C25-10 GY
C25-11 GY
C25-12 GY
C33-15 WE
C33-16 WE
C33-17 WE
GND
OSDS
5V
C108-13 WE
C108-14 WE
C108-1 WE
C108-7 WE
C108-12 WE
C108-11 WE
C108-8 WE
C108-9 WE
C108-10 WE
C108-6 WE
C108-5 WE
C108-4 WE
C108-2 WE
C108-3 WE
BVSEL
R24V
GND
MHVDR
HVCLK
RHVDR
RiSEL
TiCTL
TVSEL
THVDR
THRDR
THFDR
TiSENS
TVSENS
C102-14 LB
C102-13 BN
C102-12 PE
C102-11 BE
C102-10 RD
C102-9 DE
C102-8 PK
C102-7 BE
C102-6 YW
C102-5 GY
C102-4 GN
C102-3 BN
C102-2 LB
C102-1 PE
24V
P.GND
GND
COIN EN
F.G
FEED COUNT
EJECT COUNT
COPYING SIG
TXD
GND
RXD
GND
CON
--
GND
DREQ
ACK
RXD
TXD
GND
GND
GND
5V
5V
C29-B10 YW
C29-B11 YW
C29-B12 YW
C29-A1 WE
C29-A2 WE
C29-A3 WE
C29-A4 WE
C29-A5 WE
C29-A6 WE
C29-A7 WE
C29-A8 WE
C29-A9 WE
C29-A10 WE
C29-A11 WE
C30-1 LB
C30-2 BN
C30-3 PE
C30-4 BE
C30-5 RD
C30-6 DE
C30-7 PK
C30-8 BE
C30-9 YW
C30-10 GY
C30-11 GN
C30-12 BN
C30-13 LB
C30-14 PE
C6-1 BE
C6-2 RD
C6-3 BE
C6-4 OE
C33-14 WE
C33-13 WE
C33-12 WE
C33-11 WE
C33-10 WE
C33-9 WE
C33-8 WE
C33-7 WE
C33-6 WE
C33-5 WE
C33-4 WE
C33-3 WE
C33-2 WE
C33-1 WE
5V(200)
BYPPLSW
BYPPLSW
BYPPWSW
BYPPSW
BYPPFCL
BYPFCL
GND
BYPPWSW0
BYPPWSW1
BYPPWSW2
GND
5V
BYPPSW
GND
24V
BYPPFCL
24V
BYPFCL
C114-6 GY
C114-5 GY
C114-4 GY
C114-3 GY
C114-2 GY
C114-1 GY
C114-12 GY
C114-11 GY
C114-10 GY
C114-9 GY
C114-8 GY
C114-7 GY
C52-2
C52-1
C52-6 RD
C52-5 BE
C52-4 WE
C52-3 BE
C54-7 WE
C54-8 BE
C54-9 RD
C54-10 BE
C54-11 YW
C53-5 GN
C57-6 RD
C57-5 BE
C57-4 WE
C57-3 BE
C57-2 BN
C57-1 PK
C95-1 YW
C95-4 YW
C95-3 YW
C95-2 YW
C94-1 YW
C95-6 YW
C95-5 YW
C94-2 YW
C94-5 YW
C94-4 YW
C94-3 YW
C93-2 YW
C93-1 YW
C94-6 YW
C93-5 YW
C93-4 YW
C93-3 YW
C99-1 YW
C92-2 WE
C92-1 WE
C99-2 YW
C91-3 WE
C91-2 WE
C91-1 WE
C90-1 WE
C91-5 WE
C91-4 WE
C90-2 WE
C90-5 WE
C90-4 WE
C90-3 WE
C90-8 WE
C90-7 WE
C90-6 WE
C90-11 WE
C90-10 WE
C90-9 WE
C90-12 WE
C89-4 GY
C89-1 GY
C89-2 GY
C89-5 GY
C89-6 GY
C89-3 GY
C88-4 GY
C88-1 GY
C88-2 GY
C88-5 GY
C88-6 GY
C88-3 GY
C87-3 BE
C87-4 GN
C87-5 OE
C85-7 PK
C87-1 PE
C87-2 RD
C86-3 BN
C85-6 PE
C86-4 YW
C85-4 BE
C85-5 LB
C86-2 BE
C85-3 OE
C85-1 RD
C86-1 RD
C85-2 BE
C84-2 YW
C84-1 YW
C96-2 YW
C96-1 YW
C80-2 YW
C80-1 YW
C84-4 YW
C84-3 YW
C79-2 YW
C79-1 YW
C80-4 YW
C80-3 YW
C76-2 YW
C76-1 YW
C78-2 YW
C78-1 YW
C82-2 WE
C82-1 WE
C83-2 WE
C83-1 WE
C81-4 WE
C81-3 WE
C81-2 WE
C81-1 WE
C81-8 WE
C81-7 WE
C81-6 WE
C81-5 WE
C81-12 WE
C81-11 WE
C81-10 WE
C81-9 WE
C75-3 YW
C75-2 YW
C75-1 YW
C74-2 YW
C74-1 YW
C75-8 YW
C75-7 YW
C75-6 YW
C75-5 YW
C75-4 YW
C71-3 WE
C71-2 WE
C71-1 WE
C73-3 WE
C73-2 WE
C73-1 WE
C71-5 WE
C71-4 WE
C68-5 WE
C68-6 WE
C68-7 WE
C68-8 WE
C68-9 WE
C68-10 WE
C69-1 WE
C69-2 WE
C69-3 WE
C70-1 WE
C70-2 WE
C70-3 WE
C65-3 YW
C65-4 YW
C65-5 YW
C65-6 YW
C65-7 YW
C65-8 YW
C65-9 YW
C65-10 YW
C66-1 YW
C66-2 YW
C67-1 YW
C67-2 YW
C19-B13 YW
C19-B12 YW
C19-B11 YW
C19-B10 YW
C19-B9 YW
C19-B8 YW
C19-B19 YW
C19-B18 YW
C19-B17 YW
C19-B16 YW
C19-B15 YW
C19-B14 YW
C19-B7 YW
C21-1 RD
C19-A17 WE
C19-A16 WE
C19-A15 WE
C19-A14 WE
C19-A13 WE
C19-B6 YW
C19-B5 YW
C19-B4 YW
C19-B3 YW
C19-A19 WE
C19-A18 WE
C19-B2 YW
C19-B1 YW
C21-5 OE
C21-3 BE
C21-9 LB
C21-7 BE
C21-13 PK
C21-11 PE
C21-4 BE
C21-2 RD
C21-12 YW
C21-10 BN
C20-1 GY
C20-2 GY
C20-3 GY
C20-4 GY
C20-5 GY
C20-6 GY
C20-12 GY
C20-11 GY
C20-10 GY
C20-9 GY
C20-8 GY
C20-7 GY
C21-14 PE
C21-15 RD
C21-16 BE
C21-17 GN
C21-18 OE
C19-A1 WE
C19-A2 WE
C19-A3 WE
C19-A4 WE
C19-A5 WE
C19-A6 WE
C19-A7 WE
C19-A8 WE
C19-A9 WE
C19-A10 WE
C19-A11 WE
C19-A12 WE
C46-B8 YW
C46-B7 YW
C46-B6 YW
C46-B5 YW
C46-B4 YW
C46-B1 YW
C46-B2 YW
C46-B3 YW
C45-B16 YW
C45-B15 YW
C45-B14 YW
C45-B13 YW
C45-B12 YW
C45-B11 YW
C45-A16 WE
C45-A15 WE
C45-A14 WE
C45-A13 WE
C45-A12 WE
C45-A11 WE
C45-A10 WE
C45-A9 WE
C45-A8 WE
C45-A7 WE
C45-A6 WE
C45-A5 WE
C45-A4 WE
C45-A3 WE
C45-A2 WE
C45-A1 WE
C45-B7 YW
C45-B8 YW
C45-B9 YW
C45-B10 YW
C46-A3 WE
C46-A2 WE
C46-A1 WE
C47-A9 WE
C47-A8 WE
C47-A7 WE
C47-A10 WE
C47-A12 WE
C47-A11 WE
C47-A6 WE
C47-A5 WE
C47-A4 WE
C47-B2 YW
C47-B1 YW
C47-B4 YW
C47-B3 YW
C46-B10 YW
C46-B9 YW
C45-B2 YW
C45-B1 YW
C47-A3 WE
C47-A2 WE
C47-A1 WE
C45-B4 YW
C45-B3 YW
C45-B6 YW
C45-B5 YW
1
2
1
2
1
2
1
2
PFCL-U
UP24V
C47-B12 YW
C47-B11 YW
C47-B10 YW
C47-B9 YW
C47-B8 YW
C47-B7 YW
C47-B6 YW
C47-B5 YW
C64-1 WE
C64-2 WE
C64-3 WE
C64-4 WE
C64-5 WE
C64-6 WE
C64-7 WE
C64-8 WE
C64-9 WE
C64-10 WE
C64-11 WE
C64-12 WE
C64-13 WE
C64
C63-1 WE
C63-2 WE
C63-3 WE
C63-4 WE
C63-5 WE
C63-6 WE
C63-7 WE
C63-8 WE
C63-9 WE
C63-10 WE
C63-11 WE
C63-12 WE
C63-13 WE
C63-14 WE
C63-15 WE
C63-16 WE
C63-17 WE
C63
C60
C60-1 WE
C60-2 WE
C60-3 WE
C60-4 WE
C60-5 WE
C60-6 WE
C60-7 WE
C60-8 WE
C60-9 WE
C60-10 WE
C60-11 WE
C60-12 WE
C60-13 WE
C60-14 WE
C60-15 WE
C60-16 WE
C60-17 WE
C48-11 WE
C48-12 WE
C48-13 WE
C48-1 WE
C48-2 WE
C48-3 WE
C48-4 WE
C48-5 WE
C48-6 WE
C48-7 WE
C48-8 WE
C48-9 WE
C48-10 WE
C59-1 WE
C59-2 WE
C59-3 WE
C59-4 WE
C59-5 WE
C59-6 WE
C59-7 WE
C59-8 WE
C59-9 WE
C59-10 WE
C59-11 WE
C59-12 WE
C59-13 WE
C49-B17 WE
C49-B16 WE
C49-B15 WE
C49-B14 WE
C49-B13 WE
C49-B12 WE
C49-B11 WE
C49-B10 WE
C49-B9 WE
C49-B8 WE
C49-B7 WE
C49-B6 WE
C49-B5 WE
C49-B4 WE
C49-B3 WE
C49-B2 WE
C49-B1 WE
P.GND
R24V
LAMP OFF
S.GND
DIGLED8
DIGLED7
SCAN8
SCAN7
SCAN6
SCAN5
DIGKEY9
5V
DIGKEY4
DIGKEY5
DIGKEY6
DIGKEY7
DIGKEY8
4
3
2
1
17
16
15
14
13
12
11
10
9
8
7
6
5
C49-A17 WE
C49-A16 WE
C49-A15 WE
C49-A14 WE
C49-A13 WE
C49-A12 WE
C49-A11 WE
C49-A10 WE
C49-A9 WE
C49-A8 WE
C49-A7 WE
C49-A6 WE
C49-A5 WE
C49-A4 WE
C49-A3 WE
C49-A2 WE
C49-A1 WE
4
3
2
1
17
16
15
14
13
12
11
10
9
8
7
6
5
DIGLED6
1
2
3
DIGLED4
DIGLED5
4
5
DIGLED2
DIGLED3
6
7
SCAN4
DIGLED1
8
9
SCAN2
SCAN3
10
11
DIGKEY3
SCAN1
DIGKEY1
DIGKEY2
12
13
C6-5 RD
C6-6 RD
C6-7 BE
C6-8 BE
C6-9 OE
C6-10 OE
C6-11 BE
C6-12 BE
F2 24V
GND
F2 24V
GND
F3 5V
F3 5V
GND
GND
N.C
OFM RET
OFM CLK
OCM M1
OCM M2
OCM M2
OCM VREF
OCM CWB
OCM CLK
OCM RET
OCM ENABLE
OFM CWB
OFM RET
OFM CLK
OFM ENABLE
OFSOL(ACT)
OFM ENABLE
SBFSSOL
OFSOL(RET)
RESERVE(SOL)
EFSSOL
OFCL
SBPSOL(ACT)
SBPSOL(RET)
OSLED(GREEN)
OSLED(RED)
OSLSW
DFTSW
DFSSW2
DFSSW1
OSWSW
DF SET
RESERVE(SW)
RESERVE(SW)
OSSW
OFSW
OSBSW
N.C
C27-12A GY
C27-11A GY
C27-10A GY
C27-9A GY
C27-8A GY
C27-7A GY
C27-6A GY
C27-5A GY
C27-4A GY
C27-3A GY
C27-2A GY
C27-1A GY
C27-11B YW
C27-10B YW
C27-9B YW
C27-8B YW
C27-7B YW
C27-6B YW
C27-5B YW
C27-4B YW
C27-3B YW
C27-2B YW
C27-1B YW
C26-1 GY
C26-2 GY
C26-3 GY
C26-4 GY
C26-5 GY
C26-6 GY
C26-7 GY
C26-8 GY
C26-9 GY
C26-10 GY
C26-11 GY
C17-8 BN
C17-7 BE
C17-6 YW
C17-5 PK
C17-4 OE
C17-3 GN
C17-2 GY
C17-1 PE
DIGLED6
1
2
3
DIGLED4
DIGLED5
4
5
DIGLED2
DIGLED3
6
7
SCAN4
DIGLED1
8
9
SCAN2
SCAN3
10
11
DIGKEY3
SCAN1
DIGKEY1
DIGKEY2
12
13
C50(CN36)
VEE OFF
LCD VSS
LCD FRAME
Y2
A8
A7
A6
A5
A4
X2
A3
Y1
A2
X1
A1
BUZZER
LCD DISP OFF
LCD D2
LCD D1
LCD D0
LCD VDD
LCD VSS
LCD CP
LCD LOAD
A13
A14
A12
A9
A10
A11
LAMP OFF
R24V
P.GND
LCD D3
B2
B3
B1
A15
A16
A17
SCAN8
SCAN5
SCAN6
SCAN7
DIGLED7
DIGLED8
5V
S.GND
B10
B11
B9
B4
B5
B6
B7
B8
DIGKEY5
DIGKEY4
DIGKEY6
DIGKEY7
DIGKEY8
DIGKEY9
B17
B12
B13
B14
B15
B16
C49(CN42)
R24V
13
12
11
FSSOL2
FSSOL1
10
9
LED REM
5V(200)
8
7
EPDSW
5V
6
5
SET SIG
GND
4
3
GND
GND
JBESW
5V
2
1
C48(CN35)
GND
TCS
A8
A7
A6
A5
A4
5V
A3
5V
A2
BYPFSW
A1
GND
DVUNITN
N.C
DEVHITN
GND
TNS
5V
P0
A13
A12
A9
A10
A11
TCDSW
TNFSOL
GND
B2
B3
B1
EEDATA
DRUNITN
GND
EESCLK
CL
GND
P0
GND
B10
B11
B9
B4
B5
B6
B7
B8
N.C
5V
B12
B13
C47(CN9)
FTH
5V
A8
A7
A6
A5
A4
P0
A3
5V
A2
RSW
A1
GND
5V
GND
FTH OUT
A9
A10
GND
DUPFCL
24V
B2
B3
B1
DUP P0
R24V
SET SIG
GND
5V
DUPPCSW
B10
B9
B4
B5
B6
B7
B8
5V
FSSW
A8
A7
A6
A5
A4
GND
A3
24V
A2
FSSOL1
A1
FSSOL2
ESW
GND
CFM1 24V
5V
GND
5V
GND
A13
A14
A12
A9
A10
A11
LO24V
UP24V
PFCL-U
CCSW
GND
B2
B3
B1
A15
A16
HUMSENS
EM B-D
ETTH
GND
5V
RCL
24V
PFCL-L
B10
B11
B9
B4
B5
B6
B7
B8
CFM4 REM
R24V
EM A
EM A-D
EM B
B12
B13
B14
B15
B16
ODSW
SM VREF
SM M1
SM M2
SM M3
SM M4
SM M5
SM CLK
SM CWB
SM RET
SM ENABLE
EL REM
SHPSW
GND
LIVE
RESET
GND
GND
5V
24V
DECK
or
DESK
OPTION
NEUTRAL
FSW3 SIG
GND
RXD
GND
TXD
F1 24V
F1 24V
GND
F3 5V
GND
GND
A4
B4
A1
B1
A2
B2
A3
B3
A5
B5
A6
B6
A7
B7
A8
B8
A9
B10
A10
B9
12
11
10
9
8
7
6
5
4
1
2
3
12
11
10
9
8
7
6
5
4
1
2
3
15
14
13
12
GND
GND
12V
EVEN
SHIFT
ODD
CLP
GND
GND
5V
7
10
9
8
6
5
4
3
2
1
BYPPLSW
GND
11B
12B
GND
5V (200)
9B
10B
CFM3
8B
GND
7B
FRCSW
6B
GND
5B
TDDSW
4B
GND
3B
2B
5V
OFS
1B
BYPFCL
11A
12A
BYPPFCL
24V
9A
10A
24V
8A
GND
7A
BYPPSW
6A
5V
5A
GND
4A
BYPPWSW2
3A
2A
BYPPWSW0
BYPPWSW1
1A
OSLSW
DFTSW
11B
12B
DFSSW2
DFSSW1
9B
10B
OSWSW
8B
DF SET
7B
RESERVE(SW)
6B
RESERVE(SW)
5B
OSSW
4B
OFSW
3B
2B
OFM ENABLE
OSBSW
1B
OFSOL(ACT)
OFM ENABLE
11A
12A
SBFSSOL
OFSOL(RET)
9A
10A
RESERVE(SOL)
8A
EFSSOL
7A
OFCL
6A
SBPSOL(ACT)
5A
SBPSOL(RET)
4A
OSLED(GREEN)
3A
2A
N.C
OSLED(RED)
1A
OCM M1
11
OCM M2
OCM M2
9
10
OCM VREF
8
OCM CWB
7
OCM CLK
6
OCM RET
5
OCM ENABLE
4
OFM CWB
3
2
OFM RET
OFM CLK
1
SET SIG
RESET
11
12
RXD
GND
9
10
GND
8
TXD
7
GND
6
5V
5
GND
4
GND
3
2
F2 24V
F2 24V
1
RESET
SET SIG
1
2
N.C
N.C
9
10
N.C
8
N.C
7
N.C
6
N.C
5
GND
4
TXD
3
2
RXD
GND
1
RESET
B6
FSW3 SIG
B5
GND
B4
RXD
B3
B2
TXD
GND
B1
RESET
A6
SET SIG
A5
GND
A4
TXD
A3
A2
RXD
GND
A1
PG
PG
5V
5V
6
5
4
3
2
R24V
1
R24V
7
8
SG
SG
9
10
PFM S/S
DM S/S
11
12
PFM L/D
DM L/D
13
14
FCL1
DM CLK
15
16
GND
24V
5V
FSW1
17
18
C21(CN11)
1
2
UP24V
R24V
3
4
PWSW-U1
PWSW-U0
5
6
GND
PWSW-U2
7
8
LO24V
R24V
9
10
PWSW-L1
PWSW-L0
GND
FCL3
A8
A7
A6
A5
A4
24V
A3
5V
A2
FSW3
A1
GND
24V
GND
LM-U SW2
FCL2
SCSW
GND
5V
FSW2
A13
A14
A12
A9
A10
A11
PLSW-L
LM-L SW2
PLSW-U
GMD
GND
LM-U REM
GND
LM-U SW1
B2
B3
B1
A15
A16
A17
A18
A19
GND
GND
5V
LICSW-U
LM-L REM
GND
LM-L SW1
GND
B10
B11
B9
B4
B5
B6
B7
B8
5V
5V
PSW-L
GND
LICSW-L
GND
5V
PSW-U
B18
B19
B17
B12
B13
B14
B15
B16
C19(CN13)
5
4
3
2
1
C1-3 BE
C11-2 RD
C1-6 RD
C1-5 OE
C1-4 BE
C1-2 BE
C2-4 PK
C2-6 GN
C2-1 BN
C2-2 BE
C2-3 YW
C2-5 OE
C2-7 GY
C2-8 PE
F2 24V
6
5V
5
GND
4
GND
3
2
R24V
GND
1
LMPMON
8
GND
7
FH-S
6
FH-M
5
5V
4
ZCROSS
3
2
SLEEP
CFM5
1
C15-1 LB
C15-2 RD
C15-3 YW
C15-4 BE
12
11
K.COUNT REM
10
24V
9
SET SIG
8
GND
7
TC2 REM
6
24V
5
TC REM
4
24V
3
2
24V
MSW OFF REM
1
C12-1 BE
C12-2 RD
C12-3 BE
C12-4 OE
C13-1 RD
C13-2 RD
C13-3 BE
C13-4 BE
C13-5 OE
C13-6 OE
C13-7 BE
C51-2 RD
C51-3 RD
C51-4 RD
C51-5 RD
C51-6 BE
C51-7 BE
C51-8 BE
C51-9 BE
C52-8 RD
C52-7 BE
C53-4 OE
C53-3 BE
C52-2 BE
C52-1 RD
C56-6 RD
C56-5 RD
C56-4 RD
C56-3 BE
C56-2 BE
C56-1 BE
C10-6 RD
C10-5 OE
C10-4 BE
C10-3 BE
C10-2 BE
H LIVE
FH-S
FH-M
1
2
3
C5(CN5)
GND
PWSW-L2
11
12
F1 24V
GND
GND
GND
F3 5V
F1 24V
24V
GND
GND
5V
GND
24V
GND
GND
5V
F2 24V
1
6
5
4
3
2
5V
SLEEP
CFM5
ZCROSS
FH-M
FH-S
GND
LMPMON
7
8
6
1
2
3
4
5
GND
GND
12
GND
11
F3 24V
F3 24V
GND
GND
F2 24V
F2 24V
5V
GND
24V
GND
9
10
7
8
6
1
2
3
4
5
GND
F3 24V
GND
GND
GND
F1 24V
F1 24V
F1 24V
F1 24V
9
10
11
7
8
6
1
2
3
4
5
1
21
2
1
2
1
2
CFM4
2
12
1
3
2
1
3
2
1
C39-12 GY
2
3
1
4
1
2
3
4
CFM4 REM
R24V
1
2
1
2
1
2
1
2
DUP P0
3
2
1
3
2
1
1
2
3
3
2
1
2
1
2
1
2
3
1
4
3
1
2
1
2
3
4
5
1
2
TC2
2
1
N.C
N.C
2
1
5
4
3
2
1
1
2
3
1
2
3
11
10
4
3
2
1
9
8
7
6
5
4
3
11
10
9
8
7
6
5
3
2
1
1
2
1
2
CCSW
GND
CCSW
2
1
C45(CN16)
R24V
CFM2 REM
2
1
3
R24V
PG
DM S/S
DM L/D
DM CLK
4
3
2
1
EM A-D
EM A
1
21
2
8
8
PFM L/D
PFM S/S
SG
5V
6
7
5V
5V
GND
GND
UNIT
FEED1
1
2
3
4
5
6
7
4
5
3
2
1
4
5
3
2
1
1
2
FCL1
24V
FCL1
FSW1
5V
GND
FSW1
3
2
1
7
8
9
10
11
12
7
8
9
10
11
12
6
7
FSSW
3
2
1
3
2
1
1
2
3
4
5
6
SET SIG
GND
C46(CN10)
4
3
FSSOL2
1
ETTH
2
3
4
GND
HUMSENS
5V
HUMSENS
GND
FSSW
5V
6
5
4
3
2
1
FSSOL
24V
FSSOL1
2
1
ESW
UNIT
EJECT
ESW
EM
1
2
3
4
EM B
EM B-D
CFM1
CFM1 24V
GND
DUPLEX UNIT
OPTION
3
2
1
1
2
5
4
3
2
1
5V
DUPPCSW
GND
DUPFCL
24V
DUPFCL
DUPPCSW
UNIT
-RATION
RESIST
1
2
3
3
2
1
1
2
3
RSW
RCL
RCL
24V
GND
RSW
5V
PFCL-L
1
2
1
2
PFCL-L
LO24V
DM
1
2
3
5
PFM
R24V
PG
P0
P0
GND
1
2
2
1
BYPFSW
GND
5V
BYPFSW
3
2
1
3
2
1
3
2
1
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
REM
GND
10
9
10
9
3
2
1
1
2
3
5V
8
7
6
5
4
3
2
1
GND
TCS
2
1
2
1
TCDSW
CFM2
PFCL-U
TNFSOL
2
1
TCDSW
GND
GND
TCS
5V
TNFSOL
EEPROM
DRUM UNIT
TNS
FUSE
CL
UNIT
DEVELOPING
8
7
6
5
4
3
2
1
EEDATA
EESCLK
GND
DRUNITN
5V
TNS
GND
DVUNITN
DEVHITN
CL
P0
GND
FTH OUT
FTH
5V
1
2
1
2
3
4
5
5
4
3
2
1
1
2
3
4
5
FTH
1
2
2
1
C25(CN50)
BUILT-IN FINIHSER
OPTION
C38
7
8
9
10
11
12
1
2
3
4
5
6
6
1
2
3
4
5
12
7
8
9
10
11
RESET
SET SIG
GND
RXD
GND
TXD
GND
5V
F2 24V
GND
GND
F2 24V
2
1
3
2
1
3
6
5
4
3
2
1
6
5
4
3
2
1
FEED UNIT
LOWER
LICSW-L
PSW-L
3
2
1
1
2
3
28
17
46
35
64
53
82
71
3
2
1
1
2
3
28
17
46
35
64
53
82
71
LICSW-U
PSW-U
FEED UNIT
UPPER
5V
GND
5V
GND
5V
GND
5V
GND
OPCB-L
1
2
DREQ
ACK
TXD
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
11
5V
5V
VEE OFF
LCD D3
LCD D2
LCD D1
LCD D0
LCD DISP OFF
LCD VSS (SG)
LCD VDD (+5V)
LCD VSS (SG)
LCD CP
LCD LOAD
LCD FRAME
X2
Y1
Y2
X1
C50-13 WE
1
2
3
4
5
6
7
8
9
10
11
12
8
9
8
8
2
1
TDDSW
1
2
1
2
1
2
3
4
5
6
7
9
10
11
12
13
14
5V
PD
GND
1
2
3
5V SAFE
8
14
12
13
11
9
10
7
6
1
2
3
4
5
7
11
10
9
14
13
12
6
5
4
3
2
1
C30(CN8)
LASER SCANNER UNIT
7
6
5
4
3
2
1
1
2
3
5
4
3
2
1
PD
SCRDYN
SCCLK
PD
GND
R24V
GND
SCAN
SAMPLE
POWCONT
LASER
VDO+
VDO-
GND
19
20
1
2
2
24V
FCL3
GND
FSW3
5V
(#250)
TB2
(#250)
TB1
UNIT
INVERTER
BACK LIGHT
1
2
3
4
5
6
7
8
9
10
11
12
CCFT COLD
N.C
CCFT HOT
N.C
1
2
3
4
X1
Y1
Y2
X2
PANEL
TOUCH
LCD VSS(SG)
LCD CONT
LCD DISP OFF
LCD LOAD
LCD
LCD FRAME
LCD CP
LCD VSS(SG)
LCD D0
LCD D1
LCD VDD(+5V)
LCD D2
LCD D3
12
11
10
9
8
7
6
5
4
3
2
1
BUZZER
C50-12 WE
C50-11 WE
C50-10 WE
C50-9 WE
C50-8 WE
C50-7 WE
C50-6 WE
C50-5 WE
C50-4 WE
C50-3 WE
C50-2 WE
C50-1 WE
GND
1
2
1
2
DH
(Optional for 120V spec.
and 220-240V spec.)
6
7
1
FCL2
2
1
FCL2
24V
11
13
12
11
9
10
FSSOL2
R24V
FSSOL1
3
2
1
FSSOL
C35(CN39)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
3
1
2
3
3
2
1
17
16
15
14
13
12
11
2
1
2
1
2
1
C9(CN9)
LIVE
(#187)
TB3
C4(CN4)
5V
GND
AGND
12V
1
2
2
1
MODRXD
RXIN
MODTXD
/RINGDET
/ONHOOK2
/ONHOOK1
NCUTYPE1
/OFFHOOK
NCUTYPE3
NCUTYPE2
FAXSEL
TELSEL
EARTH
PLSDIL
SHUNT
KMUTE
EXTRING2
EXTRING1
GND
+5V
AGND
+12V
1212
22 22
12
33
34
35
36
37
38
39
40
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
FMAIN_RXD0
12
4
/SETFAX
/PREQ
/FAXREADY
/SREQ
/MAINSTS
FMAIN_TXD0
/MMISTS
FMMI_TXD2
FMMI_RXD2
/FAXRESET
/FOHSTHIN
FMIPOUT0
FMREOUT
FFOCLK
/FPVD
/FPHSYNC
/FPVSYNC
FOVSYNC
FMRE
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
FVCLK
FPVCLK
GND
M3.3V
C11-1 RD
1
2
1
2
C6(CN6)
C3(CN3)
C1(CN1)
9
10
UNIT
SEPARATER
JOB
OPTION
EPDSW
3
2
1
LED
13
12
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
10
GND
JBESW
LED REM
5V
5V(200)
EPDSW
GND
5V
GND
SET SIG
C24(CN5)
C23(CN4)
C36(CN40)
C34(CN38)
C33(CN37)
C31(CN34)
C26(CN32)
C14(CN31)
C22(CN3)
C27(CN33)
C29(CN6)
C20(CN12)
SDPCB
GND
1
2
4
3
5V
GND
24V
C12(CN6)
C41(CN2)
C44(CN5)
C43(CN4)
C40 (CN1)
ODSW
SM VREF
SM M1
SM M2
SM M3
SM M4
SM M5
SM CLK
SM CWB
SM RET
SM ENABLE
EL REM
SHPSW
GND
EL
EL ON
24V
GND
MSW
MRY
AGND
12V
N.C
GND
N.C
5V
3
C42(CN3)
OR KEY COUNTER
KEY CARD 1
OPTION
2
3
1
3
1
2
C2(CN2)
PSPCB
SUB
OPTION
NO
COM
NO
COM
24V
R24V
SSW2 SSW1
LIVE
NEUTRAL
MRY
5
4
3
2
1
5
4
3
2
1
2
GND
SIG
5V
F.G
5V
B7
5V
B6
5V
B5
5V
B4
5V
B3
5V
B2
5V
B1
5V
B0
COPY ENABLE
GND
24V
KEY CARD REM
(ONLY JAPAN)
KEY CARD MK-1
OPTION
5
F.G
OPCB-R
(ONLY JAPAN)
KMAS
OPTION
10
9
8
7
6
5
4
1
2
3
7
10
9
8
GND
RXD
-
CON
11
12
N.C
24V
6
5
4
3
2
1
GND
GND
GND
FEED COUNT
COIN EN
GND
P.GND
GND
RXD
GND
TXD
COPYING SIG
EJECT COUNT
10
6
7
8
9
4
3
2
1
(ONLY JAPAN)
COIN VENDER
OPTION
4
3
2
1
TC
2
1
C37
C39
C58
C39-6 GY
C39-1 GY
C38-1 YW
C39-2 GY
C39-5 GY
C39-4 GY
C39-3 GY
C39-7 GY
6
7
8
9
10
11
12
1
2
3
4
5
1
2
3
4
5
6
C39-8 GY
C39-9 GY
C39-11 GY
C39-10 GY
12
7
8
9
10
11
C37-1 GY
C37-4 GY
C37-3 GY
C37-2 GY
C37-5 GY
6
7
8
9
10
11
1
2
3
4
5
1
2
3
4
5
6
C37-6 GY
C37-7 GY
C37-10 GY
C37-9 GY
C37-8 GY
C37-11 GY
7
8
9
10
11
F.G
7
8
C13-8 BE
7
C38-2 YW
C38-5 YW
C38-4 YW
C38-3 YW
C38-6 YW
6
7
8
9
10
11
12
11
10
9
8
STDF or SRDF
OPTION
1
2
3
4
5
1
2
3
4
5
6
6
5
4
3
2
1
6
1
2
3
4
5
C38-7 YW
C38-8 YW
C38-11 YW
C38-10 YW
C38-9 YW
12
7
8
9
10
11
9
8
7
6
1
2
3
4
5
1
7
8
6
5
4
3
2
6
1
2
3
4
5
1
2
3
4
5
6
6
5
4
3
2
1
11
12
12
7
8
9
10
11
N.C
9
8
7
8
7
6
5
4
3
2
1
FINIHSER
OPTION
6
1
2
3
4
5
6
5
4
3
2
1
BOX
MAIL
OPTION
18
13
14
15
16
17
RESET
SET SIG
GND
TXD
GND
RXD
6
1
2
3
4
5
JBESW
2
1
3
2
1
CFM5
CFM5 REM
24V
FRCSW
2
1
5V
OFS
GND
GND
OFS
3
1
2
TDDSW
5
4
3
2
1
CFM3
1
2
FCL3
FSW3
12
11
10
9
8
3
2
1
GND
FSW2
5V
BATTERY
BACKUP
+2.4V
S.GND
SPEAKER
1
2
2
SPEAKER
S.GND
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
NCUPCB
OPTION
FAXPCB
OPTION
1
2
3
33
34
35
36
37
38
39
40
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
6
5
4
3
2
1
6
4
5
3
1
2
/B
/A
6
4
5
3
1
2
A
24V
SM
SHPSW
INPCB
OSDS
ODSW
24V
B
EL
GND
6
4
5
3
1
2
24V
GND
EL
24V
3
2
1
1
2
3
GND
SHPSW
5V
GND
ODSW
5V
CLK+
RS-
RS+
CLK-
CCDPCB
PLSW-L
GND
2
1
PLSW-U
PLSW-L
2
1
PLSW-U
LM-L
LM-U
1
2
3
4
5
1
2
3
4
5
SCSW
2
1
FSW2
5
4
3
2
1
CONVEYING UNIT
VERTICAL
GND
LM-L REM
SCSW
GND
GND
LM-L SW2
GND
LM-U REM
LM-U SW1
GND
LM-U W2
LM-L SW1
PWSW-L
LOWER DRAWER
PWSW-U
UPPER DRAWER
6
5
4
3
2
1
6
5
4
3
2
1
LICSW-L
PSW-U
PSW-L
LICSW-U
7
8
5
6
3
4
1
2
8
7
6
5
4
3
2
1
7
8
5
6
3
4
1
2
8
7
6
5
4
3
2
1
PWSW-L0
PWSW-L1
UP24V
R24V
GND
LO24V
R24V
PWSW-U0
PWSW-U1
PWSW-U2
GND
PWSW-L2
C28(CN7)
FG
HVTPCB
1
5
4
3
2
9
8
7
6
10
11
12
13
14
1
RiSEL
RHVDR
HVCLK
MHVDR
GND
R24V
BVSEL
TVSENS
TiSENS
THFDR
THRDR
THVDR
TVSEL
TiCTL
5
4
3
2
9
8
7
6
10
11
12
13
14
C10(CN2)
GND
MSW
C16-1 PE
C16-2 RD
C17(CN1)
MPCB
4
3
2
1
4
3
2
1
FIXING UNIT
MSW
PSPCB
FH-S
INLET
GROUND
COM
LIVE
170°C
FH-M
ILSW
FTS