3-1-22
2A3/4
2. To adjust the fixing pressure, tighten the fixing pressure nuts on the front and
rear of the fixing unit clockwise until each nut clamps the angle bracket against
the locking nuts underneath.
Angle bracket
Fixing pressure nut
Locking nuts
Figure 3-1-27 Adjusting the fixing pressure
3. While lifting the fixing unit release lever, slide the fixing unit back into the
machine.
4. Close the front cover.