2A3/4
3-3-9
3. Remove the connector and four screws holding the bypass paper feed unit, and
then the unit.
Screws Screws
Connector
Bypass paper feed unit
Figure 3-3-9 Detaching the bypass paper feed unit
Removing the bypass forwarding pulley
4. Remove the stop ring at the front of the bypass forwarding pulley retainer.
5. Pull out the bypass forwarding pulley shaft in the direction of the arrow, and remove
the bypass forwarding pulley.
Stop ring
Bypass forwarding pulley
Bypass forwarding pulley shaft
Bypass forwarding pulley retainer
Figure 3-3-10 Detaching the bypass forwarding pulley