2FB/2FC-4
1-5-5
Paper feed
section
27 Multiple sheets in cassette
paper feed section 4
Feed switch 2 (FSW2) does not turn off within 1500 ms of tim-
ing switch 1 (TIMSW1) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
<1590 ms (1166 ms) for 80 cpm/2046 ms (1166 ms) for 60
cpm> of timing switch 2 (TIMSW2) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
<2045 ms (1500 ms) for 80 cpm/2631 ms (1500 ms) for 60
cpm> of timing switch 3 (TIMSW3) turning on.
Feed switch 2 (FSW2) does not turn off within specified time
<1890 ms (1386 ms) for 80 cpm/2432 ms (1386 ms) for 60
cpm> of its turning on.
Feed switch 2 (FSW2) does not turn off within 670 ms of its
turning on.
Feed switch 2 (FSW2) does not turn off within 670 ms of deck
conveying switch 1 (DKCSW1) turning off.
* Description in ( ) is written for the specified time of less then
A4/11" x 8
1/2" size.
Paper con-
veying sec-
tion
28 Multiple sheets in deck
paper feed section 1
Timing switch 1 (TIMSW1) does not turn off within 700 ms of
its turning on.
Deck conveying switch 2 (DKCSW2) does not turn off within
550 ms of timing switch 1 (TIMSW1) turning off.
29 Multiple sheets in deck
paper feed section 2
Deck conveying switch 1 (DKCSW1) does not turn off within
550 ms of deck conveying switch 2 (DKCSW2) turning off.
30 Multiple sheets in optional
side feeder paper feed
section
Side feeder feed switch (SFFSW) does not turn off within 700
ms of its turning on.
32 Misfeed in registration Feed switch 1 (FSW1) does not turn on within specified time
<800 ms (586 ms) for 80 cpm/1029 ms (586 ms) for 60 cpm>
of feed switch 2 (FSW2) turning on.
* Description in ( ) is written for the specified time of less then
A4/11" x 8
1/2" size.
33 Misfeed in registration Feed switch 1 (FSW1) does not turn off within specified time
<800 ms (586 ms) for 80 cpm/1029 ms (586 ms) for 60 cpm>
of feed switch 2 (FSW2) turning on.
Feed switch 1 (FSW1) does not turn off within 666 ms of its
turning on (when paper is fed from optional side feeder).
Feed switch 1 (FSW1) does not turn off within specified time
(1181 ms for 80 cpm/1520 ms for 60 cpm) of its turning on
(when paper is fed from MP tray).
Feed switch 1 (FSW1) does not turn off within specified time
<895 ms (656 ms) for 80 cpm/1152 ms (656 ms) for 60 cpm>
of duplex conveying switch 3 (DUPCSW3) turning on (when
paper is fed from duplex section).
Feed switch 1 (FSW1) does not turn off within specified time
(800 ms for 80 cpm/1029 ms for 60 cpm) of feed switch 2
(FSW2) turning on.
Feed switch 1 (FSW1) does not turn off within specified time
(1000 ms for 80 cpm/1286 ms for 60 cpm) of its turning on
(when paper is fed from optional side feeder).
Feed switch 1 (FSW1) does not turn off within specified time
(2000 ms for 80 cpm/2573 ms for 60 cpm) of its turning on
(when paper is fed from duplex section).
Feed switch 1 (FSW1) does not turn off within specified time
(1890 ms for 80 cpm/2432 ms for 60 cpm) of its turning on
(when paper is fed from MP tray).
* Description in ( ) is written for the specified time of less then
A4/11" x 8
1/2" size.
Section Jam code Description Conditions