10-29
Troubleshooting > Troubleshooting
Images are skewed. Are the originals placed correctly?
When placing originals on the platen,
align them with the original size
indicator plates.
page 5-2
When placing originals in the
document processor, align the
original width guides securely before
placing the originals.
page 5-3
Is the paper loaded correctly? Check the position of the paper
width guides.
page 3-4
Printouts have vertical
lines.
Is the slit glass dirty? Clean the slit glass. page 10-3
― Run [Laser Scanner Cleaning]. page 10-55
Dirt on the top edge or
back of the paper.
Is the interior of the machine dirty? Open the right cover. If the machine
interior is dirty with toner, clean it
using soft, dry, lint-free cloth.
page 10-2
Part of the image is
periodically faint or shows
white lines.
― Open and then close the right cover. ―
― Run [Drum Refresh]. page 10-54
― Run [Developer Refresh]. page 10-55
Print on the back of the
sheet is visible on the
front.
― Set [Prevent Bleed-through] to
[On].
page 6-40
page 8-19
Symptom Checkpoints Corrective Actions
Reference
Page