(5) Detaching and refitting the MP unit
Procedure
1. Remove the screw and then remove the
developing fan cover.
2. Open the MP tray.
Figure 1-5-33
3. Remove two screws and then remove the
lower right rear cover.
Figure 1-5-34
4. Remove the screw and then remove the
middle right cover.
Figure 1-5-35
Developing
fan cover
MP tray
Lower right
rear cover
Screws
Middle right cover