2KN/2KP
1-5-55
(2) Detaching and refitting the cleaning blade
Follow the procedure below to replace the cleaning blade.
Procedure
1. Remove the cleaning unit (see page 1-5-
54).
2. Release two claws and then remove the
upper cleaning cover from the cleaning unit.
Figure 1-5-114
3. Remove two screws and then remove the
cleaning blade from the cleaning unit.
Figure 1-5-115
4. Replace the cleaning blade.
* When attaching the cleaning blade, adjust
two projections.
5. Refit the upper cleaning cover to the clean-
ing unit.
6. Refit the cleaning unit.
Figure 1-5-116
Cleaning unit
Upper cleaning cover
Claw
Claw
Cleaning blade
Cleaning unit
Cleaning blade
Cleaning blade
Projection
Projection