2KN/2KP
1-5-58
1-5-10 Fuser section
(1) Detaching and refitting the fuser unit
Procedure
1. Open the front cover and pull out the paper
conveying unit.
2. Remove the rear transfer guide.
3. Remove the screw from the paper convey-
ing unit front, and then remove the fuser unit
retainer.
Figure 1-5-122
4. Open the eject section and slide the fuser
unit to machine front.
Remove the fuser unit from the paper con-
veying unit.
Figure 1-5-123
5. When the fuser unit is replaced with a new
one, carry out the following procedure.
6. Perform maintenance mode U167 (clearing
the fuser count) (see page 1-3-51).
Fuser unit retainer
Fuser unit
Eject section