2KN/2KP
1-3-21
U053
Setting: separate setting
1. Select Separate setting at the screen for selecting an item.
2. Select the item to be adjusted. The selected item is displayed in reverse.
3. Change the value using the cursor up/down keys.
4. Press the start key. The value is set.
Setting: thick paper setting
1. Select Thick setting at the screen for selecting an item.
2. Select the item to be adjusted. The selected item is displayed in reverse.
3. Change the value using the cursor up/down keys.
4. Press the start key. The value is set.
Setting: transfer setting
Modify setting when faulty transfer occurs after replacing a transfer unit or a transfer belt.
1. Select TC Setting (Uneven Image) at the screen for selecting an item.
2. When the faulty transfer occurs near leading edge or trailing edge of paper (sample 1), press the numer-
ical key of Band Lead/Trail to increase the setting value.
3. When the faulty transfer occurs periodically, (sample 2), press the numerical key of Band Cycle to
decrease the setting value.
4. Press the start key. The value is set.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No.
is displayed.
Maintenance
item No.
Description
Display Description Setting
range
Default
setting
MAIN MOTOR Drive motor speed adjustment -100 to 100 7
TC MOTOR Transfer motor speed adjustment -100 to 100 10
FIX MOTOR Fuser motor speed adjustment -100 to 100 3
RESIST MOTOR Registration motor speed adjustment -100 to 100 8 (82 cpm)
6 (62 cpm)
POLYGON MOTOR Polygon motor speed adjustment -100 to 100 -6
FEED MOTOR Feed motor speed adjustment -100 to 100 8 (82 cpm)
6 (62 cpm)
Display Description Setting
range
Default
setting
TC MOTOR Transfer motor speed adjustment -100 to 100 5 (82 cpm)
4 (62 cpm)
FIX MOTOR Fuser motor speed adjustment -100 to 100 5
RESIST MOTOR Registration motor speed adjustment -100 to 100 0
FEED MOTOR Feed motor speed adjustment -100 to 100 0
70 mm
64 mm
64 mm
64 mm
Sample 1 Sample 2