Mechanical safety
Mechanical safety
Flown congurations
The K2 rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines
of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of 4 or more.
Refer to Soundvision for the safety factor of a specic deployment.
The safe limit gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-enclosure angles, etc.).
The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Always refer to Soundvision for the safety factor of a mixed array.
When ying a K2 array with a Kara downll, the mechanical safety of all system elements must be considered.
The indicated maximum limit applies to the K2 only.
Do not implement a pullback on a K2 array with a Kara downll.
K2
conguration rigging accessory safe limit maximum limit
K2-BUMP 16 24
14 K2 + 2 LA-RAK 24 K2 + 2 LA-RAK
12 K1-SB + 1 LA-RAK 16 K1-SB + 2 LA-RAK
K2-BUMP + K2-BAR
10 K1 + 2 LA-RAK 12 K1 + 2 LA-RAK
K2-LINK under K1-BUMP 16 24
own
K2-RIGBAR 12 12
own with a downll KARADOWNK2 6 Kara
K1 and K1-SB
conguration rigging accessory safe limit max limit
K1-BUMP 18 24own
K1-BUMP + KARA-
DOWNK1
16 22
KS28
conguration rigging accessory maximum / safe limit
own KS28-BUMP 16
SB28
conguration rigging accessory maximum / safe limit
ground-stacked No rigging accessory 4
own BUMPSUB 8
28 K2 owner's manual (EN) version 1.1